Description:
The AS5026.001 is a digital I/O board for the RBXM module, providing 16 digital inputs and 16 digital outputs.
Features:
- 16 digital inputs and 16 digital outputs
- Two-position jumper (RESET/HOLD) for output behavior on system misbehavior
- First input can generate an interrupt to the CPU
Technical Specifications:
-
Jumper Settings:
- RESET: Outputs set to Low State on system misbehavior
- HOLD: Outputs retain current state on system misbehavior
-
Input Words: 2 total
- Word ("BASE" + 0): Inputs 1-16 (Bit 0-15; "0" = Low State, "1" = High State)
-
Output Words: 1 total
- Word ("BASE" + 0): Outputs 1-16 (Bit 0-15; "0" = Off, "1" = On)
-
State Word: Represents supply and output transistor states (treated as Output Word)
- Bit 0: Transistor alarm outputs 1-8 (1 = Alarm)
- Bit 1: Transistor alarm outputs 9-16 (1 = Alarm)
- Bit 4: Supply alarm outputs 1-8 (1 = Alarm)
- Bit 5: Supply alarm outputs 9-16 (1 = Alarm)
-
Software Requirements:
- OSFM Version: 1.07 or higher
- RHLL Language Version: 21.04 or higher
- Microcontroller PIC Version: 2.00 or higher
ROBOX|AS5026.001| digital I/O board

Current product
Current
Vendor:
ROBOX
ROBOX|AS5026.001| digital I/O board
Regular price
$180.00
Sale price
$180.00
Regular price
$326.00
Options
Descriptions
Description:
The AS5026.001 is a digital I/O board for the RBXM module, providing 16 digital inputs and 16 digital outputs.
Features:
- 16 digital inputs and 16 digital outputs
- Two-position jumper (RESET/HOLD) for output behavior on system misbehavior
- First input can generate an interrupt to the CPU
Technical Specifications:
-
Jumper Settings:
- RESET: Outputs set to Low State on system misbehavior
- HOLD: Outputs retain current state on system misbehavior
-
Input Words: 2 total
- Word ("BASE" + 0): Inputs 1-16 (Bit 0-15; "0" = Low State, "1" = High State)
-
Output Words: 1 total
- Word ("BASE" + 0): Outputs 1-16 (Bit 0-15; "0" = Off, "1" = On)
-
State Word: Represents supply and output transistor states (treated as Output Word)
- Bit 0: Transistor alarm outputs 1-8 (1 = Alarm)
- Bit 1: Transistor alarm outputs 9-16 (1 = Alarm)
- Bit 4: Supply alarm outputs 1-8 (1 = Alarm)
- Bit 5: Supply alarm outputs 9-16 (1 = Alarm)
-