Honeywell|CC-TDOB11|Redundant I/O Terminal Adapter (IOTA)
Description
CC-TDOB11 is a redundant I/O Terminal Adapter (IOTA) designed for the Experion Series-C Discrete Output Module. It provides a reliable interface for driving discrete field devices, such as solenoids, relays, and indicator lights, with support for redundancy to ensure high availability in industrial control systems.
Features
- Redundant configuration for enhanced reliability.
- Supports 24 VDC outputs with configurable settings.
- Open-circuit detection for fault indication.
- Configurable safe-state behavior per channel: HOLD LAST STATE or SHED to SAFE STATE.
- Non-incendive output suitable for use in hazardous areas.
- Built-in diagnostics for maintenance and troubleshooting.
Technical Specifications
- Output Type: 24 VDC, transistor open-collector
- Channels: 32
- Maximum Current per Channel: 500 mA (continuous), 1 A (for 1 second)
- Maximum Power Dissipation per Channel: 1.8 W at 24 VDC, 500 mA
- Channel-to-Channel Isolation: 500 Vrms for 60 seconds
- Common-to-Channel Isolation: 500 Vrms for 60 seconds
- Open-Circuit Detection: Yes, per channel
- Output Rise Time: < 1 ms
- Output Fall Time: < 1 ms
- Operating Temperature Range: -40°C to +70°C
- Storage Temperature Range: -40°C to +85°C
- Relative Humidity: 0% to 95%, non-condensing
- Vibration Resistance: 5 to 500 Hz, 0.03 inches double amplitude
- Shock Resistance: 10 g, 11 ms, half-sine wave
- Size: 12" (Redundant)
Honeywell|CC-TDOB11|Redundant I/O Terminal Adapter (IOTA)
Honeywell|CC-TDOB11|Redundant I/O Terminal Adapter (IOTA)
Description
CC-TDOB11 is a redundant I/O Terminal Adapter (IOTA) designed for the Experion Series-C Discrete Output Module. It provides a reliable interface for driving discrete field devices, such as solenoids, relays, and indicator lights, with support for redundancy to ensure high availability in industrial control systems.
Features
- Redundant configuration for enhanced reliability.
- Supports 24 VDC outputs with configurable settings.
- Open-circuit detection for fault indication.
- Configurable safe-state behavior per channel: HOLD LAST STATE or SHED to SAFE STATE.
- Non-incendive output suitable for use in hazardous areas.
- Built-in diagnostics for maintenance and troubleshooting.
Technical Specifications
- Output Type: 24 VDC, transistor open-collector
- Channels: 32
- Maximum Current per Channel: 500 mA (continuous), 1 A (for 1 second)
- Maximum Power Dissipation per Channel: 1.8 W at 24 VDC, 500 mA
- Channel-to-Channel Isolation: 500 Vrms for 60 seconds
- Common-to-Channel Isolation: 500 Vrms for 60 seconds
- Open-Circuit Detection: Yes, per channel
- Output Rise Time: < 1 ms
- Output Fall Time: < 1 ms
- Operating Temperature Range: -40°C to +70°C
- Storage Temperature Range: -40°C to +85°C
- Relative Humidity: 0% to 95%, non-condensing
- Vibration Resistance: 5 to 500 Hz, 0.03 inches double amplitude
- Shock Resistance: 10 g, 11 ms, half-sine wave
- Size: 12" (Redundant)