Technical Specifications
Voltage Inputs:
- Range: 2 to 275Vac
- Load Relay Burden: 0.05VA at 120Vac
- Voltage Withstand: 260Vac permanent, 420Vac for 1 min/hr
Digital Inputs:
- Voltage Threshold: 20 to 230Vdc
- Impedance: >100kΩ
- Maximum Error: ±10% setting or ±5V
- Acknowledgment Time: <1ms
Analog Inputs:
- Current Ranges: 0 to -1mA, 0 to +1mA, etc.
- Conversion Range: -1 to 20dcmA
- Accuracy: ±0.2% full scale
Time Synchronization:
- IRIG-B Input: TTL level, demodulated
- Real-Time Clock: 20ppm accuracy, >1 week backup
Power Supply:
- Options: DC 24-48V, AC 120-230V
- Power: 25VA nominal, max 45VA
Outputs:
- Continuous Current: 16A, 60A for 1 second
- Trip Contacts/Output Relays
Communication:
- Front Port (COM2): RS232, baud rates up to 115200
- Protocols: ModBus RTU/DNP 3.0, IEC 60870-5-104, IEC 61850
Environmental Protection:
- IP52 rating, operating temperature: -10 to +60°C
GE Fanuc|F650CABF1G0HI10NBNA|Feeder Protection & Bay Controller


GE Fanuc|F650CABF1G0HI10NBNA|Feeder Protection & Bay Controller
Description
The GE F650CABF1G0HI10NBNA is a high-performance feeder protection and control device designed for advanced power system applications. It provides comprehensive protection functions, precise measurements, and robust communication capabilities.
Features
- Advanced protection and control
- High precision measurements
- Multiple communication options
- Robust environmental endurance
Technical Specifications
Voltage Inputs:
- Range: 2 to 275Vac
- Load Relay Burden: 0.05VA at 120Vac
- Voltage Withstand: 260Vac permanent, 420Vac for 1 min/hr
Digital Inputs:
- Voltage Threshold: 20 to 230Vdc
- Impedance: >100kΩ
- Maximum Error: ±10% setting or ±5V
- Acknowledgment Time: <1ms
Analog Inputs:
- Current Ranges: 0 to -1mA, 0 to +1mA, etc.
- Conversion Range: -1 to 20dcmA
- Accuracy: ±0.2% full scale
Time Synchronization:
- IRIG-B Input: TTL level, demodulated
- Real-Time Clock: 20ppm accuracy, >1 week backup
Power Supply:
- Options: DC 24-48V, AC 120-230V
- Power: 25VA nominal, max 45VA
Outputs:
- Continuous Current: 16A, 60A for 1 second
- Trip Contacts/Output Relays
Communication:
- Front Port (COM2): RS232, baud rates up to 115200
- Protocols: ModBus RTU/DNP 3.0, IEC 60870-5-104, IEC 61850
Environmental Protection:
- IP52 rating, operating temperature: -10 to +60°C