EL3020| ABB| Continuous Gas Analyzer
Description
The ABB EasyLine EL3020 is a 19-inch rack-mountable continuous gas analyzer designed for process and emission monitoring applications. It supports up to five measurement components and features automatic calibration, customizable outputs, and interfaces for communication with external systems. The EL3020 can be equipped with an optional integral gas feed system and offers a range of analyzers for different gas components.
Features
- Measurement Components: Up to five per analyzer.
- Automatic Calibration: Including pump and valve control.
- Simplified Calibration: Using air or integral calibration cells.
- Communication Interfaces: Modbus, Profibus, Ethernet.
- Operator Interface: Simple menu-driven with clear-text status messages.
- Housing: 19-inch rack-mount with IP20 protection.
- Integral Gas Feed: Optional, includes solenoid valve, pump, coarse filter, capillary tube, and flow sensor modules.
- Explosion Protection: Certified for use in hazardous locations (II 3G Ex nAC II T4 X) when configured with stainless steel gas lines and connectors.
- QAL3 Monitoring: Optional, for storage and analysis of device adjustment data.
Technical Specifications
-
Ambient Temperature:
- Operation: +5°C to +45°C (Uras26 with another analyzer: +5°C to +40°C)
- Storage and Transport: –25°C to +65°C
- Relative Humidity: < 75%, slight condensation allowed
- Air Circulation: Multiple housings in a 19-inch rack must be installed with at least one height unit separation.
-
Power Supply:
- Input Voltage: 100–240 V AC ± 15%/+ 10%, 50–60 Hz ± 3 Hz
- Power Consumption: Max. 187 VA
- Connection: 3-pin plug per EN 60320-1/C14 (connection cable supplied)
-
Dimensions:
- Weight: Approx. 7–15 kg
- Dimensions: 19-inch rack housing with 3 height units
-
Gas Connections:
- Sample Gas Inlet/Outlet:
- FPM hoses: Screwed fittings with hose nozzles (stainless steel 1.4305/SAE 303) for hoses with 4 mm inner diameter
- PTFE or stainless steel pipes: 1/8 NPT female thread (stainless steel 1.4305/SAE 303) for threaded connections
- Integral Gas Feed: Factory-connected sample gas inlet and outlet; requires specific configurations
- Sample Gas Inlet/Outlet:
-
Display:
- Backlit graphics display with 240 x 160-pixel resolution
- Measured value display: Numerical with physical unit, bar graph indication, up to 5 values simultaneously
- Status display: Symbols in the display; active status messages accessible directly from the measured value display
-
Operation:
- 5 keys (cursor cross and OK); menu-assisted operation
- Configuration software ECT for rarely required functions
-
Measuring Range Switch-Over:
- Manual, automatic (autorange), or externally controlled via digital inputs
- Feedback via digital outputs, independent of the selected type of measuring range switch-over
-
Analyzers:
- Uras26: Infrared photometer for CO, NO, SO2, etc.
- Limas23: Ultraviolet photometer for NO, NO2, SO2
- Magnos206: Oxygen analyzer for O2 in process gas or N2
- ZO23: Trace oxygen analyzer for O2 in pure gases (N2, CO2, Ar)
- Caldos27: Thermal conductivity analyzer for binary gas mixtures
- Electrochemical Oxygen Sensor: For O2, only with Uras26 or Limas23
EL3020| ABB| Continuous Gas Analyzer
EL3020| ABB| Continuous Gas Analyzer
Description
The ABB EasyLine EL3020 is a 19-inch rack-mountable continuous gas analyzer designed for process and emission monitoring applications. It supports up to five measurement components and features automatic calibration, customizable outputs, and interfaces for communication with external systems. The EL3020 can be equipped with an optional integral gas feed system and offers a range of analyzers for different gas components.
Features
- Measurement Components: Up to five per analyzer.
- Automatic Calibration: Including pump and valve control.
- Simplified Calibration: Using air or integral calibration cells.
- Communication Interfaces: Modbus, Profibus, Ethernet.
- Operator Interface: Simple menu-driven with clear-text status messages.
- Housing: 19-inch rack-mount with IP20 protection.
- Integral Gas Feed: Optional, includes solenoid valve, pump, coarse filter, capillary tube, and flow sensor modules.
- Explosion Protection: Certified for use in hazardous locations (II 3G Ex nAC II T4 X) when configured with stainless steel gas lines and connectors.
- QAL3 Monitoring: Optional, for storage and analysis of device adjustment data.
Technical Specifications
-
Ambient Temperature:
- Operation: +5°C to +45°C (Uras26 with another analyzer: +5°C to +40°C)
- Storage and Transport: –25°C to +65°C
- Relative Humidity: < 75%, slight condensation allowed
- Air Circulation: Multiple housings in a 19-inch rack must be installed with at least one height unit separation.
-
Power Supply:
- Input Voltage: 100–240 V AC ± 15%/+ 10%, 50–60 Hz ± 3 Hz
- Power Consumption: Max. 187 VA
- Connection: 3-pin plug per EN 60320-1/C14 (connection cable supplied)
-
Dimensions:
- Weight: Approx. 7–15 kg
- Dimensions: 19-inch rack housing with 3 height units
-
Gas Connections:
- Sample Gas Inlet/Outlet:
- FPM hoses: Screwed fittings with hose nozzles (stainless steel 1.4305/SAE 303) for hoses with 4 mm inner diameter
- PTFE or stainless steel pipes: 1/8 NPT female thread (stainless steel 1.4305/SAE 303) for threaded connections
- Integral Gas Feed: Factory-connected sample gas inlet and outlet; requires specific configurations
- Sample Gas Inlet/Outlet:
-
Display:
- Backlit graphics display with 240 x 160-pixel resolution
- Measured value display: Numerical with physical unit, bar graph indication, up to 5 values simultaneously
- Status display: Symbols in the display; active status messages accessible directly from the measured value display
-
Operation:
- 5 keys (cursor cross and OK); menu-assisted operation
- Configuration software ECT for rarely required functions
-
Measuring Range Switch-Over:
- Manual, automatic (autorange), or externally controlled via digital inputs
- Feedback via digital outputs, independent of the selected type of measuring range switch-over
-
Analyzers:
- Uras26: Infrared photometer for CO, NO, SO2, etc.
- Limas23: Ultraviolet photometer for NO, NO2, SO2
- Magnos206: Oxygen analyzer for O2 in process gas or N2
- ZO23: Trace oxygen analyzer for O2 in pure gases (N2, CO2, Ar)
- Caldos27: Thermal conductivity analyzer for binary gas mixtures
- Electrochemical Oxygen Sensor: For O2, only with Uras26 or Limas23