ABB |COMMANDER 1900 | Circular Chart Recorders
Description
COMMANDER 1900 Series Circular Chart Recorders are precision instruments designed for industrial process control, providing accurate recording of process variables.
Features
- Quality and Technology: Manufactured with over 100 years of experience, incorporating continuous innovation and the latest technology.
- Calibration Laboratory: Features a NAMAS Calibration Laboratory (No. 0255), ensuring high accuracy and reliability.
- Versatile Applications: Suitable for a wide range of industries including process control, flow measurement, gas and liquid analysis, and environmental applications.
Technical Specifications
-
Input Types:
- Millivolts: 0 to 150 mV, minimum range 5.0 mV
- Volts: 0 to 5 V, minimum range 0.1 V
- Milliamps: 0 to 50 mA, minimum range 1.0 mA
- Resistance (Low): 0 to 750 Ω, minimum range 20 Ω
- Resistance (High): 0 to 9999 Ω, minimum range 400 Ω
- Thermocouples (Types B, R, S): 0 to 3272°F / -18 to 1800°C, minimum span 1278°F / 710°C
- Thermocouples (Types E, J, K, N, T): Various temperature ranges and spans
- RTD: -328 to 1112°F / -200 to 600°C, minimum span 45°F / 25°C
-
Engineering Range:
- Engineering Range High: Up to 1000 units
- Engineering Range Low: Down to 0 units
- Minimum Span: Varies by input type (e.g., 5.0 mV for millivolts, 0.1 V for volts)
-
Pen Range:
- Pen Range High: Up to 700 units
- Pen Range Low: Down to 400 units
-
Digital Outputs:
- Up to 8 digital outputs per module
- Programmable polarity (positive or negative)
-
Analog Outputs:
- Retransmits process variables
- Adjustable retransmission range
- Output range: 4.0 to 20.0 mA
-
Relay Outputs:
- Energized by alarms, logic equation results, digital inputs, real-time events, and totalizer wrap signals
- Polarity settings for fail-safe configurations
-
Alarms:
- Time hysteresis: 0 to 9999 seconds
- Alarm delay: 0 to 250 minutes
- Enable source: Any digital signal
-
Logic Equations:
- Up to 4 logic equations
- Each equation has 7 elements
- Supports AND/OR operators
-
Function Keys:
- Function Key 1: HOME (return to Operating Page), ALMACK (acknowledge alarm)
- Function Key 2: Additional functions as required
-
Communication:
- Supports Modbus RTU protocol
-
Environmental and Mechanical:
- Temperature Units: Degrees Fahrenheit (°F), Degrees Celsius (°C)
- Performance accuracy not guaranteed below 725°F/400°C for types B, R, and S thermocouples
- Minimum span below zero: Type T 126°F/70°C, Type N 189°F/105°C
ABB |COMMANDER 1900 | Circular Chart Recorders
ABB |COMMANDER 1900 | Circular Chart Recorders
Description
COMMANDER 1900 Series Circular Chart Recorders are precision instruments designed for industrial process control, providing accurate recording of process variables.
Features
- Quality and Technology: Manufactured with over 100 years of experience, incorporating continuous innovation and the latest technology.
- Calibration Laboratory: Features a NAMAS Calibration Laboratory (No. 0255), ensuring high accuracy and reliability.
- Versatile Applications: Suitable for a wide range of industries including process control, flow measurement, gas and liquid analysis, and environmental applications.
Technical Specifications
-
Input Types:
- Millivolts: 0 to 150 mV, minimum range 5.0 mV
- Volts: 0 to 5 V, minimum range 0.1 V
- Milliamps: 0 to 50 mA, minimum range 1.0 mA
- Resistance (Low): 0 to 750 Ω, minimum range 20 Ω
- Resistance (High): 0 to 9999 Ω, minimum range 400 Ω
- Thermocouples (Types B, R, S): 0 to 3272°F / -18 to 1800°C, minimum span 1278°F / 710°C
- Thermocouples (Types E, J, K, N, T): Various temperature ranges and spans
- RTD: -328 to 1112°F / -200 to 600°C, minimum span 45°F / 25°C
-
Engineering Range:
- Engineering Range High: Up to 1000 units
- Engineering Range Low: Down to 0 units
- Minimum Span: Varies by input type (e.g., 5.0 mV for millivolts, 0.1 V for volts)
-
Pen Range:
- Pen Range High: Up to 700 units
- Pen Range Low: Down to 400 units
-
Digital Outputs:
- Up to 8 digital outputs per module
- Programmable polarity (positive or negative)
-
Analog Outputs:
- Retransmits process variables
- Adjustable retransmission range
- Output range: 4.0 to 20.0 mA
-
Relay Outputs:
- Energized by alarms, logic equation results, digital inputs, real-time events, and totalizer wrap signals
- Polarity settings for fail-safe configurations
-
Alarms:
- Time hysteresis: 0 to 9999 seconds
- Alarm delay: 0 to 250 minutes
- Enable source: Any digital signal
-
Logic Equations:
- Up to 4 logic equations
- Each equation has 7 elements
- Supports AND/OR operators
-
Function Keys:
- Function Key 1: HOME (return to Operating Page), ALMACK (acknowledge alarm)
- Function Key 2: Additional functions as required
-
Communication:
- Supports Modbus RTU protocol
-
Environmental and Mechanical:
- Temperature Units: Degrees Fahrenheit (°F), Degrees Celsius (°C)
- Performance accuracy not guaranteed below 725°F/400°C for types B, R, and S thermocouples
- Minimum span below zero: Type T 126°F/70°C, Type N 189°F/105°C