ABB |567LH-DP24|Compact Power Control Unit
Description
- Series: REOTRON 567LH-DP24
- Application Areas: Testing technology, medical technology, laser technology, thermal and chemical production processes, cathodic corrosion protection.
- Technology: Thyristor controller with phase angle or periodic group control.
- Control Options: External control signal (0...10 V DC, 0(4)...20 mA) or optional field bus interfaces (Profibus-DP, CAN-Bus, EtherCAT, DeviceNet, EtherNet/IP, ProfiNet).
Features
- High Precision Control: PI-regulator for voltage and current with adjustable percentage of P.
- Wide Input Range: Input voltage ±0…100 mV (0...10 V, DC optionally).
- Ramp Integrator: Adjustable Up/Down ramp integrator (0.1...10 Sec).
- Relay Outputs: Fault relay and status relay, each with 1 changeover contact load 250 V, 1 A.
- Temperature Monitoring: Over-temperature input switch.
- Operating Temperature: 0...45 °C.
- Compact Design: Dimensions: 140 x 290 x 160 mm.
- Field Bus Compatibility: Optional interfaces for Profibus-DP, CAN-Bus, EtherCAT, DeviceNet, EtherNet/IP, ProfiNet.
- Efficiency: > 85%.
- Power Factor: Cos Φ: 0.95.
- Protection Class: IP20 for cabinet installation.
-
Input Impedance:
- Voltage actual value: 56 kΩ
- Current actual value: 5.6 Ω
- Control Signal: Pulse enable and set point inhibit (12...24 V DC, 2.5 mA).
Technical Specifications
- Input Voltage: 3 x 400 V, ±10%, 50/60 Hz.
- Output Ripple: 100 mV/ 200 mV p-p.
-
Setpoint Input:
- Voltage: 0...+10 V DC
- Current: 0(4)...20 mA
- Potentiometer: 10 kΩ
- Internal control over display.
-
Actual Output:
- Voltage: 0...+10 V DC
- Current: 0(4)...20 mA
- Internal control over display.
- Interfaces (Optional): ProfiBus-DP, DeviceNet, CAN-Bus, ProfiNet, EtherNet/IP, EtherCAT.
- Control Accuracy: 1% of the nominal value (higher on request).
- Rating: 24 V DC or contact.
-
Relays:
- Fault relay: 1 changeover contact load 250 V, 1 A.
- Status relay: 1 changeover contact load 250 V, 1 A.
- Efficiency: > 85%.
- Power Factor: Cos Φ: 0.95.
- Operating Temperature: 0...40 °C.
- Standards: EN 50178, EN 61000-6-2, EN 61000-6-4.
- Dimensions: 140 x 290 x 160 mm.
- Weight: Not specified.
-
Input Impedance:
- Voltage actual value: 56 kΩ.
- Current actual value: 5.6 Ω.
-
Control Signal:
- Pulse enable: 12...24 V DC, 2.5 mA.
- Set point inhibit: 12...24 V DC, 2.5 mA.
- Over-Temperature Input Switch: Switch 1 mA.
- Operating Ambient Temperature: 0...45 °C.
ABB |567LH-DP24|Compact Power Control Unit
Current product
Current
Vendor:
REOTRON
ABB |567LH-DP24|Compact Power Control Unit
Regular price
$168.00
Sale price
$168.00
Regular price
$260.00
Options
Descriptions
Description
- Series: REOTRON 567LH-DP24
- Application Areas: Testing technology, medical technology, laser technology, thermal and chemical production processes, cathodic corrosion protection.
- Technology: Thyristor controller with phase angle or periodic group control.
- Control Options: External control signal (0...10 V DC, 0(4)...20 mA) or optional field bus interfaces (Profibus-DP, CAN-Bus, EtherCAT, DeviceNet, EtherNet/IP, ProfiNet).
Features
- High Precision Control: PI-regulator for voltage and current with adjustable percentage of P.
- Wide Input Range: Input voltage ±0…100 mV (0...10 V, DC optionally).
- Ramp Integrator: Adjustable Up/Down ramp integrator (0.1...10 Sec).
- Relay Outputs: Fault relay and status relay, each with 1 changeover contact load 250 V, 1 A.
- Temperature Monitoring: Over-temperature input switch.
- Operating Temperature: 0...45 °C.
- Compact Design: Dimensions: 140 x 290 x 160 mm.
- Field Bus Compatibility: Optional interfaces for Profibus-DP, CAN-Bus, EtherCAT, DeviceNet, EtherNet/IP, ProfiNet.
- Efficiency: > 85%.
- Power Factor: Cos Φ: 0.95.
- Protection Class: IP20 for cabinet installation.
-
Input Impedance:
- Voltage actual value: 56 kΩ
- Current actual value: 5.6 Ω
- Control Signal: Pulse enable and set point inhibit (12...24 V DC, 2.5 mA).
Technical Specifications
- Input Voltage: 3 x 400 V, ±10%, 50/60 Hz.
- Output Ripple: 100 mV/ 200 mV p-p.
-
Setpoint Input:
- Voltage: 0...+10 V DC
- Current: 0(4)...20 mA
- Potentiometer: 10 kΩ
- Internal control over display.
-
Actual Output:
- Voltage: 0...+10 V DC
- Current: 0(4)...20 mA
- Internal control over display.
- Interfaces (Optional): ProfiBus-DP, DeviceNet, CAN-Bus, ProfiNet, EtherNet/IP, EtherCAT.
- Control Accuracy: 1% of the nominal value (higher on request).
- Rating: 24 V DC or contact.
-
Relays:
- Fault relay: 1 changeover contact load 250 V, 1 A.
- Status relay: 1 changeover contact load 250 V, 1 A.
- Efficiency: > 85%.
- Power Factor: Cos Φ: 0.95.
- Operating Temperature: 0...40 °C.
- Standards: EN 50178, EN 61000-6-2, EN 61000-6-4.
- Dimensions: 140 x 290 x 160 mm.
- Weight: Not specified.
-
Input Impedance:
- Voltage actual value: 56 kΩ.
- Current actual value: 5.6 Ω.
-
Control Signal:
- Pulse enable: 12...24 V DC, 2.5 mA.
- Set point inhibit: 12...24 V DC, 2.5 mA.
- Over-Temperature Input Switch: Switch 1 mA.
- Operating Ambient Temperature: 0...45 °C.