Yokogawa | ANB10D-421/CU2N/NDEL | ESB Bus Node Unit
Interface Function
- Communicates: Analog I/O and contact I/O signals with the FCU via the ESB bus.
-
Options:
- Voltage: 100-120 V AC or 220-240 V AC
- Frequency: 50/60 Hz
-
Electric Power Consumption:
- 100-120 V AC: 200 VA, 120 W
- 220-240 V AC: 230 VA, 120 W
- 24 V DC: 5.5 A
Weight
- Weight: Approximately 10 kg (including 8 I/O Modules)
- Mounting Type: 19-inch rack mount (M5 x 4 screws) with insulation base (accessory)
Node Units Connectable to FCU
-
ANB10D (ESB Bus Node Units):
- Max. 3 units connected per FCU (AFV30, AFV40)
- Max. 9 units connected per FCU (AFV10, AFF55)
-
ER Bus Node Units (ANR10):
- Max. 3 units connected per FCU
- Max. 14 units connected per FCU
ESB Bus Node Connection
-
Install ESB Bus Coupler Module (EC401 or EC402) to the FCU:
- EC401 or EC402 must be installed in slot 7 and slot 8.
- For single configuration, EC401 or EC402 should be in slot 7, and slot 8 must be empty.
- EC402 can be installed in AFV30, AFV40, AFV10, or AFF55.
This structured overview provides a clear and comprehensive description of the Yokogawa ANB10D-421/CU2N/NDEL ESB Bus Node Unit, including its key technical specifications, mounting details, and connection requirements
Yokogawa | ANB10D-421/CU2N/NDEL | ESB Bus Node Unit
Yokogawa | ANB10D-421/CU2N/NDEL | ESB Bus Node Unit
Interface Function
- Communicates: Analog I/O and contact I/O signals with the FCU via the ESB bus.
-
Options:
- Voltage: 100-120 V AC or 220-240 V AC
- Frequency: 50/60 Hz
-
Electric Power Consumption:
- 100-120 V AC: 200 VA, 120 W
- 220-240 V AC: 230 VA, 120 W
- 24 V DC: 5.5 A
Weight
- Weight: Approximately 10 kg (including 8 I/O Modules)
- Mounting Type: 19-inch rack mount (M5 x 4 screws) with insulation base (accessory)
Node Units Connectable to FCU
-
ANB10D (ESB Bus Node Units):
- Max. 3 units connected per FCU (AFV30, AFV40)
- Max. 9 units connected per FCU (AFV10, AFF55)
-
ER Bus Node Units (ANR10):
- Max. 3 units connected per FCU
- Max. 14 units connected per FCU
ESB Bus Node Connection
-
Install ESB Bus Coupler Module (EC401 or EC402) to the FCU:
- EC401 or EC402 must be installed in slot 7 and slot 8.
- For single configuration, EC401 or EC402 should be in slot 7, and slot 8 must be empty.
- EC402 can be installed in AFV30, AFV40, AFV10, or AFF55.
This structured overview provides a clear and comprehensive description of the Yokogawa ANB10D-421/CU2N/NDEL ESB Bus Node Unit, including its key technical specifications, mounting details, and connection requirements