KJ3202X1-BA1 | Emerson Ovation | DO 8-Channel 24 VDC High-Side
Overview
The KJ3202X1-BA1 is an 8-channel digital output module designed by Emerson for the Ovation system. It provides high-side switching for 24 VDC applications, making it suitable for various industrial automation tasks.
Features
- High-Side Switching: Effectively controls loads with high-side outputs.
- Multiple Channels: Supports 8 channels for versatile applications.
- Robust Design: Built to withstand harsh environmental conditions.
Technical Specifications
Power Specifications
- Local Bus Power: 12 VDC at 150 mA
- Bussed Field Power: 30 VDC at 3 A
- Field Circuit: 30 VDC at 1 A/channel, 3 A/card
Environmental Specifications
- Ambient Temperature: -40°C to +70°C
- Shock Resistance: 10 g ½ sine wave for 11 ms
-
Vibration Resistance:
- 1 mm peak-to-peak from 2 to 13.2 Hz
- 0.7 g from 13.2 to 150 Hz
- Airborne Contaminants: Class G3 (ISA-S71.04 –1985)
- Relative Humidity: 5% to 95% Non-Condensing
- Terminal Block Key Position: B6
Removal and Insertion
- The unit cannot be removed or inserted with system power energized unless the area is confirmed non-hazardous. Only one unit may be handled at a time.
- Non-sparking field circuits must be de-energized before removal or insertion, including the fused terminal block.
- A rotary keying system ensures compatibility between I/O cards and terminal blocks after installation. Ensure terminal block keys are set to match the I/O card.
Maintenance and Adjustment
- The unit contains no user-serviceable parts and should not be disassembled.
- Calibration is not required.
KJ3202X1-BA1 | Emerson Ovation | DO 8-Channel 24 VDC High-Side
KJ3202X1-BA1 | Emerson Ovation | DO 8-Channel 24 VDC High-Side
Overview
The KJ3202X1-BA1 is an 8-channel digital output module designed by Emerson for the Ovation system. It provides high-side switching for 24 VDC applications, making it suitable for various industrial automation tasks.
Features
- High-Side Switching: Effectively controls loads with high-side outputs.
- Multiple Channels: Supports 8 channels for versatile applications.
- Robust Design: Built to withstand harsh environmental conditions.
Technical Specifications
Power Specifications
- Local Bus Power: 12 VDC at 150 mA
- Bussed Field Power: 30 VDC at 3 A
- Field Circuit: 30 VDC at 1 A/channel, 3 A/card
Environmental Specifications
- Ambient Temperature: -40°C to +70°C
- Shock Resistance: 10 g ½ sine wave for 11 ms
-
Vibration Resistance:
- 1 mm peak-to-peak from 2 to 13.2 Hz
- 0.7 g from 13.2 to 150 Hz
- Airborne Contaminants: Class G3 (ISA-S71.04 –1985)
- Relative Humidity: 5% to 95% Non-Condensing
- Terminal Block Key Position: B6
Removal and Insertion
- The unit cannot be removed or inserted with system power energized unless the area is confirmed non-hazardous. Only one unit may be handled at a time.
- Non-sparking field circuits must be de-energized before removal or insertion, including the fused terminal block.
- A rotary keying system ensures compatibility between I/O cards and terminal blocks after installation. Ensure terminal block keys are set to match the I/O card.
Maintenance and Adjustment
- The unit contains no user-serviceable parts and should not be disassembled.
- Calibration is not required.