ABB RLM02 Redundancy Link Module
Overview
The ABB RLM02 Redundancy Link Module enhances reliability in PROFIBUS DP/FMS networks by converting a single, non-redundant line into two reciprocally redundant lines (A/B). It operates at transmission rates between 9.6 kbit/s and 12 Mbit/s, featuring automatic line selection and comprehensive monitoring capabilities.
Benefits
- Conversion: Transforms one simple, non-redundant PROFIBUS line into two reciprocally redundant lines A/B
- Compatibility: Designed for use on PROFIBUS DP/FMS lines
- Automatic Line Selection: Ensures seamless communication
- Transmission Rate: 9.6 kbit/s to 12 Mbit/s
- Communication Monitoring: Enables real-time performance oversight
- Repeater Functionality: Extends network reach
- Redundant Power Supply: Enhances system reliability
- Status and Error Display: Provides visual feedback
- Power Supply Monitoring: Ensures consistent operation
- Alarm Contact: Offers potential-free alerts
- Easy Installation: Simple assembly on DIN mounting rail
Features
- Positioning: Can be installed directly after a master, before a bus segment with multiple slaves, or before an individual slave
- Redundant Couplers: PROFIBUS stations with redundant couplers [K] can connect directly to the PROFIBUS set redundant by RLM02
- Single Interface Stations: Can be assigned to either the A or B line
- Capacity: Each RLM02 interface supports up to 31 PROFIBUS stations
- Expansion: Using repeaters [R] and media converters [O/E] allows for increased length and number of PROFIBUS stations
Connectors / Terminals
-
Description:
- A: Redundant PROFIBUS lines, 9-pin Sub-D connector, Open
- B: Non-redundant PROFIBUS line
- M: Power supply (L1+, L2+, M), alarm (F1, F2), and earth connection (E), 8-pole terminal strips
Adjustment and Indication
-
Description:
- Act: Bus activity on line A, B, or M (yellow LED)
- Err: Error on line A, B, or M (red LED)
- Power: Power supply okay (green LED)
- Baud Rate: Rotary switch for baud rate setting (9.6 kBd ... 12 MBd)
- Reset: Button for transmission rate activation
Technical Data
Baud Rate Settings
- Switch Setting: 0 1 2 3 4 5 6 7 8 9
- Baud Rate: 12 6 3 1.5 500 187.5 93.75 19.2 9.6 No Function
- Unit: MBd or MBit/s, kBd or kbit/s
Serial Interfaces
- Connections: A, B, and M
- Transmission Rate: 9.6 kBit/s to 12 MBit/s
- Type: RS 485
- Connection: 9-pin Sub-D connector
- Electrical Isolation: To IEC/EN 61010-1, functionally isolating
- Test Voltage: 500 Veff
- Device Protection Class: IP 20
Line Length Restriction
- Master to M: 50 m
- M to Slave: 50 m
- A/B to A/B: According to PROFIBUS specification
Data Telegram Delay
- A/B to M: 11 Bit times [μs] + 0.6 μs
- M to A/B: 4 Bit times [μs] + 0.6 μs
Power Supply
- Operating Voltage: 24 VDC (+20 ... +33 V)
- Power Consumption: 120 mA typically at 24 V
- Power Loss: Approx. 3.6 W
- Connection: 8-pin terminal strip
- Wire Cross Section: 0.14 ... 1.5 mm²
Ambient Conditions
- Operating Temperature: 0 ... 55°C
- Transport / Storage Temperature: -30 ... 85°C
- Relative Humidity: Max. 75%, non-condensing in operation
- Altitude: Up to 2000 m
Alarm Contact
- Function: Normally closed / Open in case of error
- Switching Voltage: < 60 VDC
- Switching Current: Max. 1 A
Design
- Dimensions: 134 x 56 x 70 mm (H x W x D)
- Weight: Approx. 330 g
- Attachment: Mounting rail, 35 mm
- Protection: IP 20 (indoor use)
Certification
- Corrosive Atmosphere: G3 (ISA-S71.04 Severity level: G3)
- USA: UL-listed
- Canada: CSA
- Europe: CE
- Ships and Maritime Systems: DNV GL, (location class)
Accessories
- To Be Ordered Separately: 3 PROFIBUS connectors
ABB RLM02 Redundancy Link Module
ABB RLM02 Redundancy Link Module
Overview
The ABB RLM02 Redundancy Link Module enhances reliability in PROFIBUS DP/FMS networks by converting a single, non-redundant line into two reciprocally redundant lines (A/B). It operates at transmission rates between 9.6 kbit/s and 12 Mbit/s, featuring automatic line selection and comprehensive monitoring capabilities.
Benefits
- Conversion: Transforms one simple, non-redundant PROFIBUS line into two reciprocally redundant lines A/B
- Compatibility: Designed for use on PROFIBUS DP/FMS lines
- Automatic Line Selection: Ensures seamless communication
- Transmission Rate: 9.6 kbit/s to 12 Mbit/s
- Communication Monitoring: Enables real-time performance oversight
- Repeater Functionality: Extends network reach
- Redundant Power Supply: Enhances system reliability
- Status and Error Display: Provides visual feedback
- Power Supply Monitoring: Ensures consistent operation
- Alarm Contact: Offers potential-free alerts
- Easy Installation: Simple assembly on DIN mounting rail
Features
- Positioning: Can be installed directly after a master, before a bus segment with multiple slaves, or before an individual slave
- Redundant Couplers: PROFIBUS stations with redundant couplers [K] can connect directly to the PROFIBUS set redundant by RLM02
- Single Interface Stations: Can be assigned to either the A or B line
- Capacity: Each RLM02 interface supports up to 31 PROFIBUS stations
- Expansion: Using repeaters [R] and media converters [O/E] allows for increased length and number of PROFIBUS stations
Connectors / Terminals
-
Description:
- A: Redundant PROFIBUS lines, 9-pin Sub-D connector, Open
- B: Non-redundant PROFIBUS line
- M: Power supply (L1+, L2+, M), alarm (F1, F2), and earth connection (E), 8-pole terminal strips
Adjustment and Indication
-
Description:
- Act: Bus activity on line A, B, or M (yellow LED)
- Err: Error on line A, B, or M (red LED)
- Power: Power supply okay (green LED)
- Baud Rate: Rotary switch for baud rate setting (9.6 kBd ... 12 MBd)
- Reset: Button for transmission rate activation
Technical Data
Baud Rate Settings
- Switch Setting: 0 1 2 3 4 5 6 7 8 9
- Baud Rate: 12 6 3 1.5 500 187.5 93.75 19.2 9.6 No Function
- Unit: MBd or MBit/s, kBd or kbit/s
Serial Interfaces
- Connections: A, B, and M
- Transmission Rate: 9.6 kBit/s to 12 MBit/s
- Type: RS 485
- Connection: 9-pin Sub-D connector
- Electrical Isolation: To IEC/EN 61010-1, functionally isolating
- Test Voltage: 500 Veff
- Device Protection Class: IP 20
Line Length Restriction
- Master to M: 50 m
- M to Slave: 50 m
- A/B to A/B: According to PROFIBUS specification
Data Telegram Delay
- A/B to M: 11 Bit times [μs] + 0.6 μs
- M to A/B: 4 Bit times [μs] + 0.6 μs
Power Supply
- Operating Voltage: 24 VDC (+20 ... +33 V)
- Power Consumption: 120 mA typically at 24 V
- Power Loss: Approx. 3.6 W
- Connection: 8-pin terminal strip
- Wire Cross Section: 0.14 ... 1.5 mm²
Ambient Conditions
- Operating Temperature: 0 ... 55°C
- Transport / Storage Temperature: -30 ... 85°C
- Relative Humidity: Max. 75%, non-condensing in operation
- Altitude: Up to 2000 m
Alarm Contact
- Function: Normally closed / Open in case of error
- Switching Voltage: < 60 VDC
- Switching Current: Max. 1 A
Design
- Dimensions: 134 x 56 x 70 mm (H x W x D)
- Weight: Approx. 330 g
- Attachment: Mounting rail, 35 mm
- Protection: IP 20 (indoor use)
Certification
- Corrosive Atmosphere: G3 (ISA-S71.04 Severity level: G3)
- USA: UL-listed
- Canada: CSA
- Europe: CE
- Ships and Maritime Systems: DNV GL, (location class)
Accessories
- To Be Ordered Separately: 3 PROFIBUS connectors