ProSoft|MVI56E-MNETCR| Modbus TCP/IP Multi Client Enhanced Communication Module
Description
The MVI56E-MNETCR is a Modbus TCP/IP Multi Client Enhanced Communication Module for Rockwell Automation ControlLogix PACs, facilitating easy interfacing with up to 30 Modbus TCP/IP server-compatible devices. It supports remote configuration and diagnostics, enhancing performance in multi-server applications.
Features
- Supports up to 30 Clients: Faster response, reduced network traffic, minimal impact on other servers.
- RSLogix™ 5000 Integrated: Uses Add-On Instructions (AOI) or ladder files; no additional programming required.
- Remote Configuration and Diagnostics: Windows-based software for easy setup without RSLinx.
- Backward Compatible: Supports existing MVI56 ladder logic and module configurations.
- ProSoft Configuration Builder (PCB): Simplifies product and network configuration.
- 4-character alpha-numeric LED display: Shows status and diagnostic information in plain English.
Technical Specifications
General Specifications
- Backplane Compatibility: Single-slot - 1756 ControlLogix backplane
- Ethernet Port: 10/100 Mbps auto crossover detection, RJ45 connector, CAT5 cable support
- Memory Mapping: Up to 5000 16-bit registers
- Network Configuration: CIPconnect-enabled using ControlLogix 1756-ENxT/CNB modules
- Configuration Software: ProSoft Configuration Builder (PCB) for managing module configuration and diagnostics
- Add-On Instructions (AOI): For data transfer between module and processor
- Discovery Software: ProSoft Discovery Service (PDS) for locating and assigning IP addresses
Modbus TCP/IP Client Specifications
- Client Connections: Up to 30 clients, each supporting up to 16 commands
- Modbus Function Codes Supported: 1, 2, 3, 4, 5, 6, 7, 15, 16
- Floating-point Data Movement: Configurable, including Enron or Daniel® formats
- Error Codes and Status: Available from module memory through clients or RSLogix 5000 tags
Hardware Specifications
- Backplane Current Load: 800 mA @ 5 V DC, 3 mA @ 24 V DC
- Operating Temperature: 0°C to 60°C (32°F to 140°F)
- Storage Temperature: -40°C to 85°C (-40°F to 185°F)
- Shock Resistance: 30g operational, 50g non-operational
- Vibration Resistance: 5 g from 10 Hz to 150 Hz
- Relative Humidity: 5% to 95% RH, no condensation
- LED Indicators: Application Status (APP), Module Status (OK)
- Display: 4-character showing module version, IP address, application port setting, and error information
ProSoft|MVI56E-MNETCR| Modbus TCP/IP Multi Client Enhanced Communication Module


ProSoft|MVI56E-MNETCR| Modbus TCP/IP Multi Client Enhanced Communication Module
Description
The MVI56E-MNETCR is a Modbus TCP/IP Multi Client Enhanced Communication Module for Rockwell Automation ControlLogix PACs, facilitating easy interfacing with up to 30 Modbus TCP/IP server-compatible devices. It supports remote configuration and diagnostics, enhancing performance in multi-server applications.
Features
- Supports up to 30 Clients: Faster response, reduced network traffic, minimal impact on other servers.
- RSLogix™ 5000 Integrated: Uses Add-On Instructions (AOI) or ladder files; no additional programming required.
- Remote Configuration and Diagnostics: Windows-based software for easy setup without RSLinx.
- Backward Compatible: Supports existing MVI56 ladder logic and module configurations.
- ProSoft Configuration Builder (PCB): Simplifies product and network configuration.
- 4-character alpha-numeric LED display: Shows status and diagnostic information in plain English.
Technical Specifications
General Specifications
- Backplane Compatibility: Single-slot - 1756 ControlLogix backplane
- Ethernet Port: 10/100 Mbps auto crossover detection, RJ45 connector, CAT5 cable support
- Memory Mapping: Up to 5000 16-bit registers
- Network Configuration: CIPconnect-enabled using ControlLogix 1756-ENxT/CNB modules
- Configuration Software: ProSoft Configuration Builder (PCB) for managing module configuration and diagnostics
- Add-On Instructions (AOI): For data transfer between module and processor
- Discovery Software: ProSoft Discovery Service (PDS) for locating and assigning IP addresses
Modbus TCP/IP Client Specifications
- Client Connections: Up to 30 clients, each supporting up to 16 commands
- Modbus Function Codes Supported: 1, 2, 3, 4, 5, 6, 7, 15, 16
- Floating-point Data Movement: Configurable, including Enron or Daniel® formats
- Error Codes and Status: Available from module memory through clients or RSLogix 5000 tags
Hardware Specifications
- Backplane Current Load: 800 mA @ 5 V DC, 3 mA @ 24 V DC
- Operating Temperature: 0°C to 60°C (32°F to 140°F)
- Storage Temperature: -40°C to 85°C (-40°F to 185°F)
- Shock Resistance: 30g operational, 50g non-operational
- Vibration Resistance: 5 g from 10 Hz to 150 Hz
- Relative Humidity: 5% to 95% RH, no condensation
- LED Indicators: Application Status (APP), Module Status (OK)
- Display: 4-character showing module version, IP address, application port setting, and error information