Invensys Triconex|2101|Main Processor Baseplate
Description
The Model 2101 Main Processor Baseplate is a component of the Trident system, designed to accommodate up to three Main Processor (MP) Modules. Each MP Module functions as one channel within the Trident system, supporting application execution and I/O control.
Features
- Supports up to 14 I/O modules.
- Includes Ethernet TriStation and Modbus RS-232/485 connectors.
- Facilitates system diagnostics and communication tasks.
Technical Specifications
Connectors and Pin-Outs
-
Ethernet TriStation Connector:
- One connector for 10BaseT networks.
- Pins include TD+/- for data transmission and RD+/- for data reception.
-
Modbus RS-232/485 Serial Connector:
- Configurable via TriStation for RS-232 or RS-485 modes.
- Pin-out includes TD+/- for transmit data and RD+/- for receive data.
Compliance and Standards
- EMC Emissions: EN 50081-2:1993.
- EMC Immunity: EN 61131-2:1994/A11:1996, covering ESD, radiated HF fields, burst, surge, and ringwave protections.
- Product Safety: Overvoltage Category II compliant according to EN 61010-1:1993.
- CE Mark: Applied since 2000.
Installation Guidelines
- Must be installed and operated following the Trident V1.2 Planning & Installation Guide.
Invensys Triconex|2101|Main Processor Baseplate



Invensys Triconex|2101|Main Processor Baseplate
Description
The Model 2101 Main Processor Baseplate is a component of the Trident system, designed to accommodate up to three Main Processor (MP) Modules. Each MP Module functions as one channel within the Trident system, supporting application execution and I/O control.
Features
- Supports up to 14 I/O modules.
- Includes Ethernet TriStation and Modbus RS-232/485 connectors.
- Facilitates system diagnostics and communication tasks.
Technical Specifications
Connectors and Pin-Outs
-
Ethernet TriStation Connector:
- One connector for 10BaseT networks.
- Pins include TD+/- for data transmission and RD+/- for data reception.
-
Modbus RS-232/485 Serial Connector:
- Configurable via TriStation for RS-232 or RS-485 modes.
- Pin-out includes TD+/- for transmit data and RD+/- for receive data.
Compliance and Standards
- EMC Emissions: EN 50081-2:1993.
- EMC Immunity: EN 61131-2:1994/A11:1996, covering ESD, radiated HF fields, burst, surge, and ringwave protections.
- Product Safety: Overvoltage Category II compliant according to EN 61010-1:1993.
- CE Mark: Applied since 2000.
Installation Guidelines
- Must be installed and operated following the Trident V1.2 Planning & Installation Guide.