ProSoft |MVI56-MBP| Modbus Plus Communication Module
Description
The MVI56-MBP from ProSoft Technology is a Modbus Plus Communication Module designed for ControlLogix processors. It enables seamless interfacing with other Modbus Plus protocol-compatible devices, supporting both Master and Slave operations.
Features
- Master and Slave Support: Enables connection to various Modbus devices
- 4000-Word Register Space: Facilitates data exchange between the processor and Modbus Plus network
- Asynchronous Data Transfer: Ensures independent operation from the ControlLogix backplane actions
- Ladder Logic Integration: For easy configuration and data transfer
Technical Specifications
Product Model
- Model Number: MVI56-MBP
Communication Parameters
- Baud Rate: 57,600 (fixed)
- Parity: None (fixed)
- Stop Bits: 1 (fixed)
Modbus Plus Ports
- Memory Usage: User-definable
- Register Capacity: Up to 4,000 registers across the backplane
- Max Read/Write: 100 words
- Routing Levels: Supports all five levels of Modbus Plus routing
- Node Address: Configurable from 1 to 64
- Global Data Sizes: Global out: 0 to 32 words, Global in: 0 to 32 words
- Module Data Transfer: 0 to 4,000 words
- Master Command Count: 0 to 200 commands
Function Codes
- Slave Mode: Supports function codes 1, 2, 3, 4, 5, 6, 15, 16
- Master Mode: Transmits function codes 3, 16
Hardware Specifications
- Backplane Current Load: 800 mA @ 5 VDC, 3 mA @ 24 VDC
- Operating Temperature: 0°C to 60°C (32°F to 140°F)
- Storage Temperature: -40°C to 85°C (-40°F to 185°F)
- Shock Resistance: 30 g operational, 50 g non-operational
- Vibration Resistance: 5 g from 10 Hz to 150 Hz
- Relative Humidity: 5% to 95% (non-condensing)
- LED Indicators: Module status, backplane transfer status, application status, serial activity
- Debug/Configuration Port: RJ45 (DB-9M with supplied cable), RS-232 only
- Application Ports: Two DB9 Female Standard Modbus Plus connectors
- Included Accessories: RJ45 to DB-9M cable, 6-foot RS-232 configuration cable
ProSoft |MVI56-MBP| Modbus Plus Communication Module


ProSoft |MVI56-MBP| Modbus Plus Communication Module
Description
The MVI56-MBP from ProSoft Technology is a Modbus Plus Communication Module designed for ControlLogix processors. It enables seamless interfacing with other Modbus Plus protocol-compatible devices, supporting both Master and Slave operations.
Features
- Master and Slave Support: Enables connection to various Modbus devices
- 4000-Word Register Space: Facilitates data exchange between the processor and Modbus Plus network
- Asynchronous Data Transfer: Ensures independent operation from the ControlLogix backplane actions
- Ladder Logic Integration: For easy configuration and data transfer
Technical Specifications
Product Model
- Model Number: MVI56-MBP
Communication Parameters
- Baud Rate: 57,600 (fixed)
- Parity: None (fixed)
- Stop Bits: 1 (fixed)
Modbus Plus Ports
- Memory Usage: User-definable
- Register Capacity: Up to 4,000 registers across the backplane
- Max Read/Write: 100 words
- Routing Levels: Supports all five levels of Modbus Plus routing
- Node Address: Configurable from 1 to 64
- Global Data Sizes: Global out: 0 to 32 words, Global in: 0 to 32 words
- Module Data Transfer: 0 to 4,000 words
- Master Command Count: 0 to 200 commands
Function Codes
- Slave Mode: Supports function codes 1, 2, 3, 4, 5, 6, 15, 16
- Master Mode: Transmits function codes 3, 16
Hardware Specifications
- Backplane Current Load: 800 mA @ 5 VDC, 3 mA @ 24 VDC
- Operating Temperature: 0°C to 60°C (32°F to 140°F)
- Storage Temperature: -40°C to 85°C (-40°F to 185°F)
- Shock Resistance: 30 g operational, 50 g non-operational
- Vibration Resistance: 5 g from 10 Hz to 150 Hz
- Relative Humidity: 5% to 95% (non-condensing)
- LED Indicators: Module status, backplane transfer status, application status, serial activity
- Debug/Configuration Port: RJ45 (DB-9M with supplied cable), RS-232 only
- Application Ports: Two DB9 Female Standard Modbus Plus connectors
- Included Accessories: RJ45 to DB-9M cable, 6-foot RS-232 configuration cable