ABB|PFCL201CE-20KN|High-Precision Load Cell
Description
The ABB PFCL 201CE-20KN is a high-precision load cell designed for measuring strip tension in industrial applications. It features robust construction using stainless steel (SIS 2387, DIN X4CrNiMo 165) and offers excellent accuracy with minimal linearity deviation and hysteresis.
Features
- High precision measurement
- Stainless steel construction
- Excellent accuracy and repeatability
Technical Specifications
Performance
- Accuracy class: ±0.5%
- Linearity deviation: <±0.3%
- Repeatability error: <±0.05%
- Hysteresis: <0.2%
Temperature Characteristics
- Compensated temperature range: +20 to +80°C
-
Zero point drift:
- Compensated: 50 ppm/K
- Working: 100 ppm/K
-
Sensitivity drift:
- Compensated: 100 ppm/K
- Working: 200 ppm/K
- Working temperature range: -10 to +90°C
- Storage temperature range: -40 to +90°C
Mechanical
- Nominal load: 20 kN
- Maximum permitted load: 10 × Fnom
- Overload capacity: Limited by mounting screws
Electrical
- Signal output: Alternating voltage converted to DC voltage proportional to applied force
- Primary winding current: 0.5 A/330 Hz
- Output impedance: 9-12 Ω
Installation and Maintenance
- Cable installation must avoid forces acting in the measuring direction.
- Mounting requires careful alignment and torque tightening of screws.
- Regular maintenance checks are recommended to ensure optimal performance.
ABB|PFCL201CE-20KN|High-Precision Load Cell

ABB|PFCL201CE-20KN|High-Precision Load Cell
Description
The ABB PFCL 201CE-20KN is a high-precision load cell designed for measuring strip tension in industrial applications. It features robust construction using stainless steel (SIS 2387, DIN X4CrNiMo 165) and offers excellent accuracy with minimal linearity deviation and hysteresis.
Features
- High precision measurement
- Stainless steel construction
- Excellent accuracy and repeatability
Technical Specifications
Performance
- Accuracy class: ±0.5%
- Linearity deviation: <±0.3%
- Repeatability error: <±0.05%
- Hysteresis: <0.2%
Temperature Characteristics
- Compensated temperature range: +20 to +80°C
-
Zero point drift:
- Compensated: 50 ppm/K
- Working: 100 ppm/K
-
Sensitivity drift:
- Compensated: 100 ppm/K
- Working: 200 ppm/K
- Working temperature range: -10 to +90°C
- Storage temperature range: -40 to +90°C
Mechanical
- Nominal load: 20 kN
- Maximum permitted load: 10 × Fnom
- Overload capacity: Limited by mounting screws
Electrical
- Signal output: Alternating voltage converted to DC voltage proportional to applied force
- Primary winding current: 0.5 A/330 Hz
- Output impedance: 9-12 Ω
Installation and Maintenance
- Cable installation must avoid forces acting in the measuring direction.
- Mounting requires careful alignment and torque tightening of screws.
- Regular maintenance checks are recommended to ensure optimal performance.