The AAR145-S00 is a Yokogawa RTD/POT Input Module featuring 16 isolated input channels designed to support various signal types, including thermocouples, millivolt signals, RTDs, and potentiometers.
Input Channels
-
Number of Input Channels: 16, isolated channels
-
Input Signal Types:
- Thermocouple (TC): Types J, K, E, B, R, S, T, N (JIS C1602:1995, IEC584:1995)
- Millivolt (mV): -100 to 150 mV, -20 to 80 mV
- Resistance Temperature Detector (RTD): Pt100, 3-wire type (JIS C1604:1997, IEC751:1995)
- Potentiometer (POT): 100 Ω to 10 kΩ total resistance
-
Span Resistance: Must be 50% or larger of total resistance
Switching Input Signals
- Channel Selection: TC/mV and RTD/POT can be selected independently for channels 1 to 16
Voltage and Withstand Ratings
- Allowable Input Voltage: ±5 V
-
Withstanding Voltage:
- Between Input and System: 500 V AC (1500 V AC for a single card) for 1 minute
- Between Input Channels: 200 V AC for 1 minute
Resistance and Accuracy
- Input Resistance (Power ON): 1 MΩ or higher
- RTD Accuracy: ±150 mΩ
- POT Accuracy: ±0.2% / FS
- Allowable Total Resistance of Signal Source plus Wiring: 150 Ω or less (per wire)
Additional Specifications
- Measurement Current (RTD): 1 mA
- Data Update Period: 1 second
- Burn-Out Detection: Configurable for all channels (available or unavailable with UP/DOWN settings); detection time of 60 seconds
-
Temperature Drift:
- RTD: ±0.3 Ω per 10 °C
- POT: ±0.4% per 10 °C
Power and Weight
- Maximum Current Consumption: 350 mA (5 V DC)
- Weight: 0.3 kg
External Connection Options
- Dedicated Cable: KS8/AKB335
AAR145-S00 | Yokogawa | RTD/POT Input Module
AAR145-S00 | Yokogawa | RTD/POT Input Module
General Information
The AAR145-S00 is a Yokogawa RTD/POT Input Module featuring 16 isolated input channels designed to support various signal types, including thermocouples, millivolt signals, RTDs, and potentiometers.
Input Channels
-
Number of Input Channels: 16, isolated channels
-
Input Signal Types:
- Thermocouple (TC): Types J, K, E, B, R, S, T, N (JIS C1602:1995, IEC584:1995)
- Millivolt (mV): -100 to 150 mV, -20 to 80 mV
- Resistance Temperature Detector (RTD): Pt100, 3-wire type (JIS C1604:1997, IEC751:1995)
- Potentiometer (POT): 100 Ω to 10 kΩ total resistance
-
Span Resistance: Must be 50% or larger of total resistance
Switching Input Signals
- Channel Selection: TC/mV and RTD/POT can be selected independently for channels 1 to 16
Voltage and Withstand Ratings
- Allowable Input Voltage: ±5 V
-
Withstanding Voltage:
- Between Input and System: 500 V AC (1500 V AC for a single card) for 1 minute
- Between Input Channels: 200 V AC for 1 minute
Resistance and Accuracy
- Input Resistance (Power ON): 1 MΩ or higher
- RTD Accuracy: ±150 mΩ
- POT Accuracy: ±0.2% / FS
- Allowable Total Resistance of Signal Source plus Wiring: 150 Ω or less (per wire)
Additional Specifications
- Measurement Current (RTD): 1 mA
- Data Update Period: 1 second
- Burn-Out Detection: Configurable for all channels (available or unavailable with UP/DOWN settings); detection time of 60 seconds
-
Temperature Drift:
- RTD: ±0.3 Ω per 10 °C
- POT: ±0.4% per 10 °C
Power and Weight
- Maximum Current Consumption: 350 mA (5 V DC)
- Weight: 0.3 kg
External Connection Options
- Dedicated Cable: KS8/AKB335