Functionalities:
- Function: Converts digital signals from the Triconex system into continuous analog output signals for controlling field devices like valves or actuators .
- Communication: Receives three digital output tables, one for each channel, from the main processor . Selects the appropriate table to generate the analog output signal .
- Channels: Provides two independent analog output channels .
- Digital-to-Analog Converter (DAC): Each channel has its own DAC to ensure accurate conversion of digital signals to analog voltage or current .
-
Safety Features:
- Triple Modular Redundant (TMR) design: Likely incorporates redundant circuitry for fault tolerance, although some sources don't explicitly mention it .
- Continuous monitoring: Continuously monitors the health of the module and the output signal for potential issues .
-
Output Specifications:
- Output type may vary depending on the specific model, but it can provide current or voltage output within a certain range.
- You can find the exact output specifications by referring to the user manuals or datasheets for the Triconex AO3481.
Applications:
- Controlling valve position in critical pipelines.
- Regulating flow rate of process fluids .
- Positioning dampers in ventilation systems.
Triconex | AO3481 | Analog Output Module | 100% Genuine
Current product
Current
Vendor:
Triconex
Triconex | AO3481 | Analog Output Module | 100% Genuine
Regular price
$100.00
Sale price
$100.00
Regular price
$300.00
Options
Descriptions
Product Description
Functionalities:
- Function: Converts digital signals from the Triconex system into continuous analog output signals for controlling field devices like valves or actuators .
- Communication: Receives three digital output tables, one for each channel, from the main processor . Selects the appropriate table to generate the analog output signal .
- Channels: Provides two independent analog output channels .
- Digital-to-Analog Converter (DAC): Each channel has its own DAC to ensure accurate conversion of digital signals to analog voltage or current .
-
Safety Features:
- Triple Modular Redundant (TMR) design: Likely incorporates redundant circuitry for fault tolerance, although some sources don't explicitly mention it .
- Continuous monitoring: Continuously monitors the health of the module and the output signal for potential issues .
-
Output Specifications:
- Output type may vary depending on the specific model, but it can provide current or voltage output within a certain range.
- You can find the exact output specifications by referring to the user manuals or datasheets for the Triconex AO3481.
Applications:
- Controlling valve position in critical pipelines.
- Regulating flow rate of process fluids .
- Positioning dampers in ventilation systems.