ICS Triplex |T8314|Trusted Fibre TX/RX Unit
Description
The Trusted Fibre Transmitter/Receiver (Tx/Rx) Unit T8314 extends the Trusted Expander Bus over distances of up to 10 km, allowing a Trusted Expander Chassis to be located remotely from the Trusted System. It converts differential copper-based signals to fiber optic signals for transmission via single-mode fiber optic cable, ensuring reliable communication in industrial environments. For distances exceeding 2 km, it is recommended to survey the cable route.
Features
- Dual 24 Vdc Power Supply: Diode ORed for redundancy.
- Easy Installation: DIN rail mounting.
- Long-Distance Communication: Supports up to 10 km.
- Independent Units: Easy maintenance and non-interfering operation.
- SC Connectors: Square Connector type for two fibers (Tx and Rx).
- Low Power Consumption.
Technical Specifications
- Transmission Distance: Up to 10 km.
- Fiber Type: Single-mode fiber optic cable.
- Connectors: SC type connectors for Tx and Rx.
- Power Supply: Dual 24 Vdc diode ORed.
- Power Consumption: Low power.
- Mounting: DIN rail.
- Operating Temperature: Not specified in provided content.
- Storage Temperature: Not specified in provided content.
- Relative Humidity: Not specified in provided content.
- Signal Conversion: Converts differential copper signals to fiber optic signals.
- Isolation: Includes isolator, filter, and termination circuits.
- Signal Type: Positive Emitter Coupled Logic (PECL).
- Cable Type: Trusted Expander Cable TC-302 for connection to the Controller Chassis.
- Transceiver: Fiber-optic transceiver for signal conversion.
- Filtering: Incorporates filter/termination circuit and ‘π’ filter for signal processing.
ICS Triplex |T8314|Trusted Fibre TX/RX Unit
ICS Triplex |T8314|Trusted Fibre TX/RX Unit
Description
The Trusted Fibre Transmitter/Receiver (Tx/Rx) Unit T8314 extends the Trusted Expander Bus over distances of up to 10 km, allowing a Trusted Expander Chassis to be located remotely from the Trusted System. It converts differential copper-based signals to fiber optic signals for transmission via single-mode fiber optic cable, ensuring reliable communication in industrial environments. For distances exceeding 2 km, it is recommended to survey the cable route.
Features
- Dual 24 Vdc Power Supply: Diode ORed for redundancy.
- Easy Installation: DIN rail mounting.
- Long-Distance Communication: Supports up to 10 km.
- Independent Units: Easy maintenance and non-interfering operation.
- SC Connectors: Square Connector type for two fibers (Tx and Rx).
- Low Power Consumption.
Technical Specifications
- Transmission Distance: Up to 10 km.
- Fiber Type: Single-mode fiber optic cable.
- Connectors: SC type connectors for Tx and Rx.
- Power Supply: Dual 24 Vdc diode ORed.
- Power Consumption: Low power.
- Mounting: DIN rail.
- Operating Temperature: Not specified in provided content.
- Storage Temperature: Not specified in provided content.
- Relative Humidity: Not specified in provided content.
- Signal Conversion: Converts differential copper signals to fiber optic signals.
- Isolation: Includes isolator, filter, and termination circuits.
- Signal Type: Positive Emitter Coupled Logic (PECL).
- Cable Type: Trusted Expander Cable TC-302 for connection to the Controller Chassis.
- Transceiver: Fiber-optic transceiver for signal conversion.
- Filtering: Incorporates filter/termination circuit and ‘π’ filter for signal processing.