The 2108B2003N Searchpoint Optima Plus is an advanced Point-Infrared (PIR) flammable gas detector certified for use in potentially explosive atmospheres. It is designed to provide reliable and accurate detection of hydrocarbon gases and vapors.

Measuring Range

  • Range: 0-100% LEL
  • Calibrations: Wide selection of hydrocarbon gas and vapor calibrations
  • Specialist Applications: Different measuring ranges and solvent calibrations available

Signal Output

  • Analog Output: 4-20mA autosensing sink or source
  • Inhibit: 1-3mA (Default 2mA)
  • Warning: 0-6mA (Default 3mA)
  • Fault: 0mA (HART® units adjustable to 1mA)
  • Over Range: 20-21.5mA (Default 21mA)

Digital Output

  • Modbus RS485: Optional multidrop Modbus RS485 (via DX100(M))
  • HART®: Optional HART® over 4-20mA output (HART® version 7)

Physical Specifications

  • Material: 316 stainless steel
  • Weight: 1.6 kg

Performance

  • Accuracy:
    • Hydrocarbon: Baseline < ±1% FSD, 50% FSD
    • Ethylene: Baseline < ±2% FSD, 50% FSD
  • Repeatability: < ±2% FSD at 50% FSD
  • Linearity: < 5% FSD
  • Response Time:
    • T50: < 3 seconds (methane)
    • T90: < 4 seconds (methane)

Operational and Certified

  • Temperature Range: -40°C to +65°C
  • Long-Term Stability:
    • Baseline:
      • Methane 100% LEL Range: ≤ ±2% FSD
      • Ethylene 100% LEL Range: ≤ ±4% FSD
    • 50% FSD:
      • Methane 100% LEL Range: ≤ ±4% FSD
      • Ethylene 100% LEL Range: ≤ ±5% FSD
  • Drift Over Temperature Range (-40°C to 65°C):
    • Baseline: ≤ ±2% FSD
    • 50% FSD:
      • Methane 100% LEL Range: ≤ ±0.131% FSD per °C
      • Ethylene 100% LEL Range: ≤ ±0.078% FSD per °C
  • Variation with Pressure: 0.1% (of reading) per mbar

Power Supply

  • Voltage: 18-32Vdc (24Vdc nominal)
  • Power Consumption: < 4.5W max

Environmental Protection

  • IP Rating: IP 66 / 67

Diagnostics and Re-calibration

  • Methods: Via certified hand-held interrogator or optional HART® communications

Performance Approvals

  • Standards: CSA C22.2 152, FM ANSI/ISA-12.13.01, EN 60079-29-1 (BVS 03 ATEX G 016 X)
  • Functional Safety: IEC61508 Safety Integrity Level 2
Order and Warranty Information

Terms of Purchase and Returns

Detailed guidelines on minimum order quantity, delivery times, payment options, warranty, and return policies.

We gladly accept bulk orders, with a minimum order quantity of just one unit.

Upon request, we can provide all necessary documents, including Certificates of Origin/Conformance and other required export paperwork.

We accept 100% T/T (Telegraphic Transfer) payment before shipping. For items with lead times, a 30% deposit is required upfront, with the remaining 70% payable before shipment. For RMB transfers, please contact us if you have an agent in China.

All new and original items come with a standard one-year warranty. For extended warranty options, feel free to contact us for pricing details.

We prioritize your satisfaction. If you need to return an item, it must be done within 30 days of purchase. The product must be unused, unopened, and in its original packaging, including all accessories. Refunds will be processed within 5-7 business days of receiving the return. Please note, shipping and handling charges are non-refundable.

Product comparison