The FGM-6300S is a Fixed Gas Detector by Honeywell, designed for detecting flammable, toxic, and oxygen gas hazards with a wide range of applications. It features a universal transmitter with standard configurations for 3-wire, 4-20mA, and RS485 MODBUS output.
Features
- Universal Transmitter: Compatible with various gases, providing flexible detection options.
- Configurable Output: Fully configurable 4-20mA output with optional HART® 7.2 protocol.
- Relay Outputs: Includes selectable relays with configurable alarm and fault settings.
- Communication: RS485 with Modbus RTU, with optional Bluetooth (pending).
- Rugged Construction: Made from aluminum alloy or 316 stainless steel for durability.
- Mounting: Integral mounting plate with mounting holes for wall or pipe installation.
Technical Specifications
- Input Voltage: 16-32 VDC (24VDC nominal)
- Max Power Consumption: Electrochemical Cells: 5.5W; Catalytic or NDIR: 7.5W
-
Current Output: 4-20mA (source type), with default configuration:
- 1mA Fault
- 2mA Inhibit (during configuration/setup)
- 3mA Warning
- 4-20mA Normal
- 22mA Overrange
- Terminals: 5 terminals (14 terminals with relay output), wire diameter 0.5mm² (20AWG) to 2.5mm² (13AWG)
- Relays: 3 x 2A@30VDC, normally open/closed, energised/de-energised, latch/non-latch
- Communication: RS485, Modbus RTU
- Optional Bluetooth: Pending
Construction
- Transmitter Housing Material: Aluminum Alloy or 316 Stainless Steel
- Sensor Housing Material: 316 Stainless Steel
-
Weight:
- Aluminum Alloy: 3.0kg
- Stainless Steel: 5.0kg
- Mounting: Integral mounting plate with 4 x mounting holes suitable for M8 bolts (for wall/pipe installation)
- Entries: 2 x 3/4'' NPT cable/conduit entries, 1 x M25 sensor entry (with plug supplied for single entry use)
Performance
- Repeatability: <2%
- Response Time: Depending on sensor
Environment
-
IP Rating:
- Toxic and Oxygen: IP66/67
- CAT/NDIR: IP66
- Operating Temperature: -40°C to +70°C
-
Operating Humidity:
- CAT/NDIR: 0-95% RH (Non-condensing)
- Toxic gas and oxygen: 15% - 95% RH (Non-condensing)
- Operating Pressure: 90-110kPa
- Storage Conditions: -20°C to +50°C, 45-75% RH (Non-condensing), in clean air
Honeywell | FGM-6300S | Fixed Gas Detector
Honeywell | FGM-6300S | Fixed Gas Detector
Overview
The FGM-6300S is a Fixed Gas Detector by Honeywell, designed for detecting flammable, toxic, and oxygen gas hazards with a wide range of applications. It features a universal transmitter with standard configurations for 3-wire, 4-20mA, and RS485 MODBUS output.
Features
- Universal Transmitter: Compatible with various gases, providing flexible detection options.
- Configurable Output: Fully configurable 4-20mA output with optional HART® 7.2 protocol.
- Relay Outputs: Includes selectable relays with configurable alarm and fault settings.
- Communication: RS485 with Modbus RTU, with optional Bluetooth (pending).
- Rugged Construction: Made from aluminum alloy or 316 stainless steel for durability.
- Mounting: Integral mounting plate with mounting holes for wall or pipe installation.
Technical Specifications
- Input Voltage: 16-32 VDC (24VDC nominal)
- Max Power Consumption: Electrochemical Cells: 5.5W; Catalytic or NDIR: 7.5W
-
Current Output: 4-20mA (source type), with default configuration:
- 1mA Fault
- 2mA Inhibit (during configuration/setup)
- 3mA Warning
- 4-20mA Normal
- 22mA Overrange
- Terminals: 5 terminals (14 terminals with relay output), wire diameter 0.5mm² (20AWG) to 2.5mm² (13AWG)
- Relays: 3 x 2A@30VDC, normally open/closed, energised/de-energised, latch/non-latch
- Communication: RS485, Modbus RTU
- Optional Bluetooth: Pending
Construction
- Transmitter Housing Material: Aluminum Alloy or 316 Stainless Steel
- Sensor Housing Material: 316 Stainless Steel
-
Weight:
- Aluminum Alloy: 3.0kg
- Stainless Steel: 5.0kg
- Mounting: Integral mounting plate with 4 x mounting holes suitable for M8 bolts (for wall/pipe installation)
- Entries: 2 x 3/4'' NPT cable/conduit entries, 1 x M25 sensor entry (with plug supplied for single entry use)
Performance
- Repeatability: <2%
- Response Time: Depending on sensor
Environment
-
IP Rating:
- Toxic and Oxygen: IP66/67
- CAT/NDIR: IP66
- Operating Temperature: -40°C to +70°C
-
Operating Humidity:
- CAT/NDIR: 0-95% RH (Non-condensing)
- Toxic gas and oxygen: 15% - 95% RH (Non-condensing)
- Operating Pressure: 90-110kPa
- Storage Conditions: -20°C to +50°C, 45-75% RH (Non-condensing), in clean air