GE |L90-V03-HKH-F8L-H6C-L6C-U6C-W7R|Line Current Differential Relay
Description
The L90-V03-HKH-F8L-H6C-L6C-U6C-W7R is a sophisticated line differential protection relay designed for high reliability and performance in power system protection, control, and monitoring. It supports a wide range of applications, from overhead lines to underground cables, and offers advanced features such as dynamic charging current compensation and multi-ended fault location.
Features
- Phase Segregated Differential Protection: Ensures secure high-speed single pole tripping.
- IEC 61850 Compliance: Supports industry-standard protocols for seamless integration into monitoring and SCADA systems.
- Advanced Fault Recording: Includes oscillography and event recording for detailed post-event analysis.
- Flexible I/O Configuration: Modular design allows for easy configuration and future upgrades.
- Network Security: Robust security features ensure critical infrastructure protection.
Technical Specifications
-
Communication Protocols:
- IEC61850
- DNP3.0
- IEC 60870-5-104
- Modbus RTU, Modbus TCP/IP
-
Ethernet Options:
- RS485 + Multi-mode ST 10BaseF
- RS485 + Multi-mode ST Redundant 10BaseF
- RS485 + Multi-mode ST 100BaseFX
- RS485 + Multi-mode ST Redundant 100BaseFX
- RS485 + 10/100 BaseT
- RS485 + 6 port, 100 Mbps, Managed Ethernet Switch
-
Mounting Options:
- Horizontal (19" rack) - Standard
- Horizontal (19" rack) - Harsh Chemical Environment Option
- Vertical (3/4 size) - Standard
- Vertical (3/4 size) - Harsh Chemical Environment Option
-
Power Supply:
- 125/250 V AC/DC
- 125/250 V AC/DC with redundant 125/250 V AC/DC
- 24-48 V DC only
-
CT/VT Inputs:
- 8L Standard 4CT/4VT with enhanced diagnostics
- 8N Standard 8CT with enhanced diagnostics
GE |L90-V03-HKH-F8L-H6C-L6C-U6C-W7R|Line Current Differential Relay
GE |L90-V03-HKH-F8L-H6C-L6C-U6C-W7R|Line Current Differential Relay
Description
The L90-V03-HKH-F8L-H6C-L6C-U6C-W7R is a sophisticated line differential protection relay designed for high reliability and performance in power system protection, control, and monitoring. It supports a wide range of applications, from overhead lines to underground cables, and offers advanced features such as dynamic charging current compensation and multi-ended fault location.
Features
- Phase Segregated Differential Protection: Ensures secure high-speed single pole tripping.
- IEC 61850 Compliance: Supports industry-standard protocols for seamless integration into monitoring and SCADA systems.
- Advanced Fault Recording: Includes oscillography and event recording for detailed post-event analysis.
- Flexible I/O Configuration: Modular design allows for easy configuration and future upgrades.
- Network Security: Robust security features ensure critical infrastructure protection.
Technical Specifications
-
Communication Protocols:
- IEC61850
- DNP3.0
- IEC 60870-5-104
- Modbus RTU, Modbus TCP/IP
-
Ethernet Options:
- RS485 + Multi-mode ST 10BaseF
- RS485 + Multi-mode ST Redundant 10BaseF
- RS485 + Multi-mode ST 100BaseFX
- RS485 + Multi-mode ST Redundant 100BaseFX
- RS485 + 10/100 BaseT
- RS485 + 6 port, 100 Mbps, Managed Ethernet Switch
-
Mounting Options:
- Horizontal (19" rack) - Standard
- Horizontal (19" rack) - Harsh Chemical Environment Option
- Vertical (3/4 size) - Standard
- Vertical (3/4 size) - Harsh Chemical Environment Option
-
Power Supply:
- 125/250 V AC/DC
- 125/250 V AC/DC with redundant 125/250 V AC/DC
- 24-48 V DC only
-
CT/VT Inputs:
- 8L Standard 4CT/4VT with enhanced diagnostics
- 8N Standard 8CT with enhanced diagnostics