DS200LPPAG1AAA | General Electric | Line Protection Panel Board
Overview
The General Electric DS200LPPAG1AAA is a Line Protection Panel Board originally designed for the Mark V Turbine Control System Series. This PCB is used for protection and control in turbine systems.
Features
- Legacy Technology: Part of GE's Mark V series with Speedtronic control system.
- Customizable Functionality: Includes jumpers and terminal blocks for various configurations.
- Diagnostic Tools: Equipped with a diagnostic tool for easy fault detection and monitoring.
Hardware and Specifications
Jumper Configuration
- JP1, JP2, JP3: MOV or AC line filter blown fuse indication jumpers.
- JP4, JP7: AC or DC side connection analog ground current sensing jumpers.
- JP5: Grounding resistor bridge voltage application jumper.
- JP6: SCR ripple filter jumper.
Terminal Blocks
- Number of Terminals: 2 terminal blocks, 3 terminals each.
- Mounting: Installed on standoffs within the drive component.
Diagnostic and Troubleshooting
- Diagnostic Interface: Access through a menu on the drive's control panel to generate health reports.
- Data Logging: The diagnostic results can be saved and analyzed before and after repairs.
- Tools: Menu-driven interface for diagnostics, with the option to upload or download data via a serial connection.
Applications
- Turbine Systems: Used for line protection in the GE Mark V Turbine Control System.
- Industrial Automation: Essential for power and performance monitoring in turbine and generator operations.
DS200LPPAG1AAA | General Electric | Line Protection Panel Board
Current product
Current
Vendor:
GE Fanuc
DS200LPPAG1AAA | General Electric | Line Protection Panel Board
Regular price
$250.00
Sale price
$250.00
Regular price
$560.00
Options
Descriptions
Overview
The General Electric DS200LPPAG1AAA is a Line Protection Panel Board originally designed for the Mark V Turbine Control System Series. This PCB is used for protection and control in turbine systems.
Features
- Legacy Technology: Part of GE's Mark V series with Speedtronic control system.
- Customizable Functionality: Includes jumpers and terminal blocks for various configurations.
- Diagnostic Tools: Equipped with a diagnostic tool for easy fault detection and monitoring.
Hardware and Specifications
Jumper Configuration
- JP1, JP2, JP3: MOV or AC line filter blown fuse indication jumpers.
- JP4, JP7: AC or DC side connection analog ground current sensing jumpers.
- JP5: Grounding resistor bridge voltage application jumper.
- JP6: SCR ripple filter jumper.
Terminal Blocks
- Number of Terminals: 2 terminal blocks, 3 terminals each.
- Mounting: Installed on standoffs within the drive component.
Diagnostic and Troubleshooting
- Diagnostic Interface: Access through a menu on the drive's control panel to generate health reports.
- Data Logging: The diagnostic results can be saved and analyzed before and after repairs.
- Tools: Menu-driven interface for diagnostics, with the option to upload or download data via a serial connection.
Applications
- Turbine Systems: Used for line protection in the GE Mark V Turbine Control System.
- Industrial Automation: Essential for power and performance monitoring in turbine and generator operations.