GE Fanuc | 469-P5-HI-A20 | Motor Management Relay Multilin
Description
The 469-P5-HI-A20 is a Motor Management Relay from GE Multilin, designed to enhance motor protection and diagnostics. It features RTD inputs for temperature measurement, metering for system monitoring, and 4-20mA analog outputs. It integrates with EnerVista 469 software for motor system analysis.
Features
- RTD Inputs: Multiple three-wire RTDs for temperature measurement
- RTD Types: 100 Ω Nickel, 120 Ω Nickel, 10 Ω Copper, 100 Ω Platinum
- Analog Outputs: Four 4-20 mA outputs for fault detection
- Display: Standard display for monitoring
- Control Power: 90-300 VDC and 70-265 VAC at 48-62 Hz
- Phase Current Inputs: 1 A Phase CT secondaries
- Case Mounting: Panel or 19-inch rack mount
Specifications
- Series: 469 Motor Management Relay
- RTD Settings: Configurable via setpoint system
- Software Integration: EnerVista 469 for data analysis
- Analog Output: 4-20 mA for clear fault detection
Benefits
- Enhanced Monitoring: Tracks voltage, frequency, and demand
- Data Analysis: Export and trend data for maintenance
Integration and Safety
- Seamless Software Integration: Works with EnerVista software
- Motor Life Extension: Safeguards and extends motor life
Installation
- Mounting: Flexible panel or 19-inch rack mount options
GE Fanuc | 469-P5-HI-A20 | Motor Management Relay Multilin
GE Fanuc | 469-P5-HI-A20 | Motor Management Relay Multilin
Description
The 469-P5-HI-A20 is a Motor Management Relay from GE Multilin, designed to enhance motor protection and diagnostics. It features RTD inputs for temperature measurement, metering for system monitoring, and 4-20mA analog outputs. It integrates with EnerVista 469 software for motor system analysis.
Features
- RTD Inputs: Multiple three-wire RTDs for temperature measurement
- RTD Types: 100 Ω Nickel, 120 Ω Nickel, 10 Ω Copper, 100 Ω Platinum
- Analog Outputs: Four 4-20 mA outputs for fault detection
- Display: Standard display for monitoring
- Control Power: 90-300 VDC and 70-265 VAC at 48-62 Hz
- Phase Current Inputs: 1 A Phase CT secondaries
- Case Mounting: Panel or 19-inch rack mount
Specifications
- Series: 469 Motor Management Relay
- RTD Settings: Configurable via setpoint system
- Software Integration: EnerVista 469 for data analysis
- Analog Output: 4-20 mA for clear fault detection
Benefits
- Enhanced Monitoring: Tracks voltage, frequency, and demand
- Data Analysis: Export and trend data for maintenance
Integration and Safety
- Seamless Software Integration: Works with EnerVista software
- Motor Life Extension: Safeguards and extends motor life
Installation
- Mounting: Flexible panel or 19-inch rack mount options