ABB PM858K02 Controller - AC 800M Controllers
General Information
- Article Number: 3BSE082896R1 (PM858K02)
- Redundancy: Yes
- High Integrity: No
- Clock Frequency: 33 MHz
- Performance, 1000 Boolean Operations: 0.36 ms
- Performance: 0.36 ms
- Memory: 16 MB
- RAM Available for Application: 7.147 MB
- Flash Memory for Storage: Yes
Detailed Data
- Processor Type: MPC866
- Switch Over Time in Redundant Configuration: Max 10 ms
- Number of Applications per Controller: 32
- Number of Programs per Application: 64
- Number of Diagrams per Application: 128
- Number of Tasks per Controller: 32
- Number of Different Cycle Times: 32
- Cycle Time per Application Programs: Down to 1 ms
- Flash PROM for Firmware Storage: 4 MB
- Power Supply: 24 V DC (19.2-30 V DC)
- Power Consumption +24 V Typ/Max: 210 / 360 mA
- Power Dissipation: 5.1 W (8.6 W max)
- Redundant Power Supply Status Input: Yes
- Built-in Backup Battery: Lithium, 3.6 V
- Clock Synchronization: 1 ms between AC 800M controllers by CNCP protocol
- Event Queue in Controller per OPC Client: Up to 3000 events
- AC 800M Transmission Speed to OPC Server: 36-86 events/sec, 113-143 data messages/sec
- Communication Modules on CEX Bus: 12
- Supply Current on CEX Bus: Max 2.4 A
- I/O Clusters on Modulebus with Non-redundant CPU: 1 electrical + 7 optical
- I/O Clusters on Modulebus with Redundant CPU: 7 optical
- I/O Capacity on Modulebus: Max 96 (single PM866) or 84 (redundant PM866) I/O modules
- Modulebus Scan Rate: 0 - 100 ms (actual time depending on number of I/O modules)
-
Supply Current on Electrical Modulebus:
- 24 V: Max 1.0 A
- 5 V: Max 1.5 A
- Ethernet Channels: 2
- Ethernet Interface: Ethernet (IEEE 802.3), 10 Mbit/s, RJ-45, female (8-pole)
- Control Network Protocol: MMS (Manufacturing Message Service) and IAC (Inter Application Communication)
- Recommended Control Network Backbone: 100 Mbit/s switched Ethernet
- Real-time Clock Stability: 100 ppm (approx. 1 h/year)
- RS-232C Interface: 2 (one general, 1 for service tool)
- RS-232C Interface (COM3) (Non-redundant only): RS-232C, 75-19200 baud, RJ-45 female (8-pole), not opto isolated, full RTS-CTS support
- RS-232C Interface (COM4) (Non-redundant only): RS-232C, 9600 baud, RJ-45 female (8-pole), opto isolated, no RTS-CTS support
Dimensions
- Width: 119 mm (4.7 in.)
- Height: 186 mm (7.3 in.)
- Depth: 135 mm (5.3 in.)
-
Weight (Including Base):
- K01: 1200 g (2.6 lbs)
- K02: 2700 g (5.95 lbs)
ABB PM858K02 Controller - AC 800M Controllers
Current product
Current
Vendor:
ABB
ABB PM858K02 Controller - AC 800M Controllers
Regular price
$178.00
Sale price
$178.00
Regular price
$436.00
Options
Descriptions
General Information
- Article Number: 3BSE082896R1 (PM858K02)
- Redundancy: Yes
- High Integrity: No
- Clock Frequency: 33 MHz
- Performance, 1000 Boolean Operations: 0.36 ms
- Performance: 0.36 ms
- Memory: 16 MB
- RAM Available for Application: 7.147 MB
- Flash Memory for Storage: Yes
Detailed Data
- Processor Type: MPC866
- Switch Over Time in Redundant Configuration: Max 10 ms
- Number of Applications per Controller: 32
- Number of Programs per Application: 64
- Number of Diagrams per Application: 128
- Number of Tasks per Controller: 32
- Number of Different Cycle Times: 32
- Cycle Time per Application Programs: Down to 1 ms
- Flash PROM for Firmware Storage: 4 MB
- Power Supply: 24 V DC (19.2-30 V DC)
- Power Consumption +24 V Typ/Max: 210 / 360 mA
- Power Dissipation: 5.1 W (8.6 W max)
- Redundant Power Supply Status Input: Yes
- Built-in Backup Battery: Lithium, 3.6 V
- Clock Synchronization: 1 ms between AC 800M controllers by CNCP protocol
- Event Queue in Controller per OPC Client: Up to 3000 events
- AC 800M Transmission Speed to OPC Server: 36-86 events/sec, 113-143 data messages/sec
- Communication Modules on CEX Bus: 12
- Supply Current on CEX Bus: Max 2.4 A
- I/O Clusters on Modulebus with Non-redundant CPU: 1 electrical + 7 optical
- I/O Clusters on Modulebus with Redundant CPU: 7 optical
- I/O Capacity on Modulebus: Max 96 (single PM866) or 84 (redundant PM866) I/O modules
- Modulebus Scan Rate: 0 - 100 ms (actual time depending on number of I/O modules)
-
Supply Current on Electrical Modulebus:
- 24 V: Max 1.0 A
- 5 V: Max 1.5 A
- Ethernet Channels: 2
- Ethernet Interface: Ethernet (IEEE 802.3), 10 Mbit/s, RJ-45, female (8-pole)
- Control Network Protocol: MMS (Manufacturing Message Service) and IAC (Inter Application Communication)
- Recommended Control Network Backbone: 100 Mbit/s switched Ethernet
- Real-time Clock Stability: 100 ppm (approx. 1 h/year)
- RS-232C Interface: 2 (one general, 1 for service tool)
- RS-232C Interface (COM3) (Non-redundant only): RS-232C, 75-19200 baud, RJ-45 female (8-pole), not opto isolated, full RTS-CTS support
- RS-232C Interface (COM4) (Non-redundant only): RS-232C, 9600 baud, RJ-45 female (8-pole), opto isolated, no RTS-CTS support
Dimensions
- Width: 119 mm (4.7 in.)
- Height: 186 mm (7.3 in.)
- Depth: 135 mm (5.3 in.)
-
Weight (Including Base):
- K01: 1200 g (2.6 lbs)
- K02: 2700 g (5.95 lbs)