KJ3201X1-BA1 | Emerson Ovation | DI Card 24v Dry Contact
Power Specifications
- Local Bus Power: 12 VDC at 150 mA
- Bussed Field Power: 24 VDC at 100 mA
- Field Circuit: 24 VDC at 5 mA/channel
Environmental Specifications
- Ambient Temperature: -40 °C to +70 °C
- Shock: 10 g half-sine wave for 11 ms
-
Vibration:
- 1 mm peak to peak from 2 to 13.2 Hz
- 0.7 g from 13.2 to 150 Hz
- Airborne Contaminants: ISA-S71.04 –1985 Airborne Contaminants Class G3
- Relative Humidity: 5 to 95% Non-Condensing
- Terminal Block Key Position: B1
Removal and Insertion
-
Field power supplied to this device, either at the field terminal or as bussed field power through the carrier, must be removed before removing or connecting the device.
-
An I/O loop assessment must be complete on all energy-limited nodes.
-
This unit cannot be removed or inserted with system power energized.
-
Non-sparking field circuits MUST be de-energized before removing and inserting, including the fused terminal block.
-
A rotary keying system ensures compatibility between I/O cards and terminal blocks after installation is complete. The terminal block must have the keys set for the I/O card with which it is to be used.
Maintenance and Adjustment
- This unit contains no user serviceable parts and should not be disassembled for any reason.
- Calibration is not required.
KJ3201X1-BA1 | Emerson Ovation | DI Card 24v Dry Contact
KJ3201X1-BA1 | Emerson Ovation | DI Card 24v Dry Contact
Power Specifications
- Local Bus Power: 12 VDC at 150 mA
- Bussed Field Power: 24 VDC at 100 mA
- Field Circuit: 24 VDC at 5 mA/channel
Environmental Specifications
- Ambient Temperature: -40 °C to +70 °C
- Shock: 10 g half-sine wave for 11 ms
-
Vibration:
- 1 mm peak to peak from 2 to 13.2 Hz
- 0.7 g from 13.2 to 150 Hz
- Airborne Contaminants: ISA-S71.04 –1985 Airborne Contaminants Class G3
- Relative Humidity: 5 to 95% Non-Condensing
- Terminal Block Key Position: B1
Removal and Insertion
-
Field power supplied to this device, either at the field terminal or as bussed field power through the carrier, must be removed before removing or connecting the device.
-
An I/O loop assessment must be complete on all energy-limited nodes.
-
This unit cannot be removed or inserted with system power energized.
-
Non-sparking field circuits MUST be de-energized before removing and inserting, including the fused terminal block.
-
A rotary keying system ensures compatibility between I/O cards and terminal blocks after installation is complete. The terminal block must have the keys set for the I/O card with which it is to be used.
Maintenance and Adjustment
- This unit contains no user serviceable parts and should not be disassembled for any reason.
- Calibration is not required.