MMS 6310| Epro | Dual Channel Key-Pulse Monitor
Description
- MMS 6310: A dual channel key-pulse monitor designed to detect key pulses from rotating shafts using pulse sensors in combination with key-marks or triggering wheels. It is used for monitoring and protection of turbomachines, compressors, fans, centrifuges, and other machines.
Features
- Dual independent channels: Each channel can detect key pulses from different shafts running at different speeds.
- Replaceable during operation: Can be replaced while the system is running.
- Stand-alone use possible: Operates independently if needed.
- Redundant supply inputs: Ensures reliability with multiple power sources.
- Extended self-checking facilities: Built-in sensor self-test features.
- RS 232 interface: For local configuration and readout.
- RS 485 interface: For communication with epro's Analysis and Diagnostic System MMS 6850.
- Compatible with eddy-current type transducer systems: PR 6422/.. to PR 6425/.. with CON 0., PR 9376/.., and PR 6453/.. pulse sensors.
Technical Specifications
-
Sensor Inputs:
- Two independent differential inputs for pulse sensors.
- Compatible with PR 6422/.. to PR 6425/.. with CON 0., PR 9376/.., and PR 6453/..
- Input resistance: > 100 kΩ
- Input voltage range: 0 ... ±27.3 V dc
- Maximum permissible input voltage range: 0 ... 30 V
- Input frequency range: 0 ... 20000 Hz
- Automatic or manual trigger level adjustment (minimum input level for automatic tracing: 2 V)
-
Sensor Supply:
- Separate buffered sensor supply voltage for each channel: + or -26.75 Volts dc
- Available current: nominal 20 mA / maximum 35 mA
-
Key-pulse Outputs:
- One open-collector output per channel: Rectangular key-pulses inverted to the input, galvanically separated.
- Pulse duration: 1 ms
- Frequency range: 0 ... 20 kHz
- Load resistance: > 10 kΩ
-
Binary Outputs:
- Maximum voltage: 48 V dc
- Maximum current: 100 mA
-
Power Supply:
- Redundant supply inputs through two power inputs, diode decoupled.
- Power voltage: 18 ... 24 ... 31.2 V DC (IEC 654-2, category DC4)
- Power consumption: max. 4 W (max. 170 mA @ 24 V)
-
Dimensions:
- PCB/EURO card format: DIN 41494 (100 x 160 mm)
- Width: 30.0 mm (6 TE)
- Height: 128.4 mm (3 HE)
- Length: 160.0 mm
- Net weight: approx. 320 g
- Gross weight: approx. 450 g (including standard export packing)
- Packing volume: approx. 2.5 dm³
-
Environmental Conditions:
- Protection class: Module IP 00 (DIN 40050), front panel IP 21 (DIN 40050)
- Allowable relative humidity: 5 ... 95%, non-condensing
- Allowable vibration: IEC 68-2, part 6
- Vibration amplitude: 0.15 mm within 10 ... 55 Hz range
- Vibration acceleration: 16.6 m/s² within 55 ... 150 Hz range
- Allowable shock: IEC 68-2, part 29, peak acceleration: 98 m/s², nominal shock duration: 16 ms
- EMC immunity: EN 50081-1 / EN 50082-2
- Operating temperature range: 0 ... +65°C
- Storage and transport temperature range: -30 ... +85°C
-
Configuration PC Requirements:
- Processor: 486 DX, 33 MHz
- Capacity of fixed disk: min. 5 MB
- Required working memory: min. 620 KB
- Interfaces: one free RS 232 interface (COM 1 or COM 2) with FIFO type 156550 UART
- Operating system: MS DOS Version 6.22 or higher, WIN95/98, or NT 4.0
MMS 6310| Epro | Dual Channel Key-Pulse Monitor


Current product
Current
Vendor:
EPRO
MMS 6310| Epro | Dual Channel Key-Pulse Monitor
Regular price
$250.00
Sale price
$250.00
Regular price
$500.00
Options
Descriptions
Description
- MMS 6310: A dual channel key-pulse monitor designed to detect key pulses from rotating shafts using pulse sensors in combination with key-marks or triggering wheels. It is used for monitoring and protection of turbomachines, compressors, fans, centrifuges, and other machines.
Features
- Dual independent channels: Each channel can detect key pulses from different shafts running at different speeds.
- Replaceable during operation: Can be replaced while the system is running.
- Stand-alone use possible: Operates independently if needed.
- Redundant supply inputs: Ensures reliability with multiple power sources.
- Extended self-checking facilities: Built-in sensor self-test features.
- RS 232 interface: For local configuration and readout.
- RS 485 interface: For communication with epro's Analysis and Diagnostic System MMS 6850.
- Compatible with eddy-current type transducer systems: PR 6422/.. to PR 6425/.. with CON 0., PR 9376/.., and PR 6453/.. pulse sensors.
Technical Specifications
-
Sensor Inputs:
- Two independent differential inputs for pulse sensors.
- Compatible with PR 6422/.. to PR 6425/.. with CON 0., PR 9376/.., and PR 6453/..
- Input resistance: > 100 kΩ
- Input voltage range: 0 ... ±27.3 V dc
- Maximum permissible input voltage range: 0 ... 30 V
- Input frequency range: 0 ... 20000 Hz
- Automatic or manual trigger level adjustment (minimum input level for automatic tracing: 2 V)
-
Sensor Supply:
- Separate buffered sensor supply voltage for each channel: + or -26.75 Volts dc
- Available current: nominal 20 mA / maximum 35 mA
-
Key-pulse Outputs:
- One open-collector output per channel: Rectangular key-pulses inverted to the input, galvanically separated.
- Pulse duration: 1 ms
- Frequency range: 0 ... 20 kHz
- Load resistance: > 10 kΩ
-
Binary Outputs:
- Maximum voltage: 48 V dc
- Maximum current: 100 mA
-
Power Supply:
- Redundant supply inputs through two power inputs, diode decoupled.
- Power voltage: 18 ... 24 ... 31.2 V DC (IEC 654-2, category DC4)
- Power consumption: max. 4 W (max. 170 mA @ 24 V)
-
Dimensions:
- PCB/EURO card format: DIN 41494 (100 x 160 mm)
- Width: 30.0 mm (6 TE)
- Height: 128.4 mm (3 HE)
- Length: 160.0 mm
- Net weight: approx. 320 g
- Gross weight: approx. 450 g (including standard export packing)
- Packing volume: approx. 2.5 dm³
-
Environmental Conditions:
- Protection class: Module IP 00 (DIN 40050), front panel IP 21 (DIN 40050)
- Allowable relative humidity: 5 ... 95%, non-condensing
- Allowable vibration: IEC 68-2, part 6
- Vibration amplitude: 0.15 mm within 10 ... 55 Hz range
- Vibration acceleration: 16.6 m/s² within 55 ... 150 Hz range
- Allowable shock: IEC 68-2, part 29, peak acceleration: 98 m/s², nominal shock duration: 16 ms
- EMC immunity: EN 50081-1 / EN 50082-2
- Operating temperature range: 0 ... +65°C
- Storage and transport temperature range: -30 ... +85°C
-
Configuration PC Requirements:
- Processor: 486 DX, 33 MHz
- Capacity of fixed disk: min. 5 MB
- Required working memory: min. 620 KB
- Interfaces: one free RS 232 interface (COM 1 or COM 2) with FIFO type 156550 UART
- Operating system: MS DOS Version 6.22 or higher, WIN95/98, or NT 4.0