BENTLY NEVADA 288055-01: STANDARD TRANSIENT DATA INTERFACE MODULE
-
Specifications
Inputs:
- Power Consumption: 10.5 Watts
Data:
- Front Panel: 115.2 kbaud maximum RS232 serial communications
- 10Base-T / 100Base-TX I/O: 10Base-T or 100Base-TX Ethernet, autosensing
- 100Base-FX I/O: 100Base-FX Fiber-Optic Ethernet
Operating Conditions:
- Operating Temperature: -30 °C to +65 °C (-22 °F to +149 °F)
- Storage Temperature: -40 °C to +85 °C (-40 °F to +185 °F)
- Humidity: 95%, non-condensing
Battery Life:
- Powered TDI: 38 years @ 50°C (122 °F)
- Un-powered TDI: 12 years @ 50°C (122 °F)
Hazardous Area Approvals:
- North American Approval Option (01): Class 1, Div 2, Groups A, B, C, D, T4 @ Ta = -20 °C to +65 ºC (-4 ºF to +150 ºF)
- North American Approval Option (02): Ex nC[L] IIC, Class 1, Zone 2, Class 1, Div 2, Groups A, B, C, D, T4 @ Ta = -20 °C to +65 ºC (-4 ºF to +150 ºF)
- ATEX Approval Option (02): II 3/(3) G, Ex nC[L] IIC, T4 @ Ta = -20 °C to +65 ºC (-4 ºF to +150 ºF)
Physical:
- TDI Module Dimensions (Height x Width x Depth): 241.3 mm x 24.4 mm x 241.8 mm (9.50 in x 0.96 in x 9.52 in)
- Weight: 0.91 kg (2.0 lbs)
Bently Nevada|3500/22M 288055-01|Standard Transient Data Interface Module
Current product
Current
Vendor:
BENTLY NEVADA
Bently Nevada|3500/22M 288055-01|Standard Transient Data Interface Module
Regular price
$100.00
Sale price
$100.00
Regular price
$300.00
Options
Descriptions
Product Description
BENTLY NEVADA 288055-01: STANDARD TRANSIENT DATA INTERFACE MODULE
-
Specifications
Inputs:
- Power Consumption: 10.5 Watts
Data:
- Front Panel: 115.2 kbaud maximum RS232 serial communications
- 10Base-T / 100Base-TX I/O: 10Base-T or 100Base-TX Ethernet, autosensing
- 100Base-FX I/O: 100Base-FX Fiber-Optic Ethernet
Operating Conditions:
- Operating Temperature: -30 °C to +65 °C (-22 °F to +149 °F)
- Storage Temperature: -40 °C to +85 °C (-40 °F to +185 °F)
- Humidity: 95%, non-condensing
Battery Life:
- Powered TDI: 38 years @ 50°C (122 °F)
- Un-powered TDI: 12 years @ 50°C (122 °F)
Hazardous Area Approvals:
- North American Approval Option (01): Class 1, Div 2, Groups A, B, C, D, T4 @ Ta = -20 °C to +65 ºC (-4 ºF to +150 ºF)
- North American Approval Option (02): Ex nC[L] IIC, Class 1, Zone 2, Class 1, Div 2, Groups A, B, C, D, T4 @ Ta = -20 °C to +65 ºC (-4 ºF to +150 ºF)
- ATEX Approval Option (02): II 3/(3) G, Ex nC[L] IIC, T4 @ Ta = -20 °C to +65 ºC (-4 ºF to +150 ºF)
Physical:
- TDI Module Dimensions (Height x Width x Depth): 241.3 mm x 24.4 mm x 241.8 mm (9.50 in x 0.96 in x 9.52 in)
- Weight: 0.91 kg (2.0 lbs)