1771-P6S1| Allen-Bradley |Power Supply Module
Description
The 1771-P6S1 is an Allen-Bradley power supply module designed for industrial automation, providing a stable 5V DC output for backplane use in I/O chassis. It supports local or remote sensing configurations and includes a P/S ACTIVE indicator for monitoring.
Features
- Wide input voltage range
- Stable 5V DC output
- Parallel operation capability
- 5-position terminal block included
Technical Specifications
- Input Voltage: 240V AC (187 to 264V AC RMS)
- Frequency: 47 to 63 Hz
- Output Voltage: 5V DC ±2%
- Output Current: 6A maximum
- Power Consumption: 30 VA maximum
- Protection Fuse: 1.5A 250V slow-blow
- Operational Temperature: 0 to 60°C
- Storage Temperature: -40 to 85°C
- Relative Humidity: 5 to 95% (non-condensing)
-
Physical Dimensions:
- Width: 1 slot in I/O chassis
- Height: 2.5 inches (63.5 mm)
- Depth: 5.25 inches (133.35 mm)
- Weight: 1.85 lbs (0.84 kg)
- Terminal Block: 5-position, accepts single 14 AWG wires
- Parallel Operation: Requires paralleling cable; must ensure simultaneous power-up to prevent overcurrent shutdown
- Installation: Wire connections should be made with the power supply turned off to avoid potential damage or injury
1771-P6S1| Allen-Bradley |Power Supply Module
1771-P6S1| Allen-Bradley |Power Supply Module
Description
The 1771-P6S1 is an Allen-Bradley power supply module designed for industrial automation, providing a stable 5V DC output for backplane use in I/O chassis. It supports local or remote sensing configurations and includes a P/S ACTIVE indicator for monitoring.
Features
- Wide input voltage range
- Stable 5V DC output
- Parallel operation capability
- 5-position terminal block included
Technical Specifications
- Input Voltage: 240V AC (187 to 264V AC RMS)
- Frequency: 47 to 63 Hz
- Output Voltage: 5V DC ±2%
- Output Current: 6A maximum
- Power Consumption: 30 VA maximum
- Protection Fuse: 1.5A 250V slow-blow
- Operational Temperature: 0 to 60°C
- Storage Temperature: -40 to 85°C
- Relative Humidity: 5 to 95% (non-condensing)
-
Physical Dimensions:
- Width: 1 slot in I/O chassis
- Height: 2.5 inches (63.5 mm)
- Depth: 5.25 inches (133.35 mm)
- Weight: 1.85 lbs (0.84 kg)
- Terminal Block: 5-position, accepts single 14 AWG wires
- Parallel Operation: Requires paralleling cable; must ensure simultaneous power-up to prevent overcurrent shutdown
- Installation: Wire connections should be made with the power supply turned off to avoid potential damage or injury