Yokogawa |CP401-10 | Processor Module
Description
The Yokogawa CP401-10 is a reliable and efficient power supply module designed to support Yokogawa’s distributed control systems (DCS) and other automation applications. It provides stable DC power, ensuring consistent performance and reliability in various industrial environments. The module integrates seamlessly with Yokogawa’s system infrastructure, delivering secure power to essential components.
Technical Specifications
- Model Number: CP401-10
- Type: Power Supply Module
- Input Voltage Range: 100 to 240 V AC
- Input Frequency: 50/60 Hz
- Output Voltage: 24 V DC nominal
- Output Current: 10 A maximum
- Efficiency: ≥85% at full load
- Protection: Overload, over-voltage, and short-circuit protection
- Cooling Method: Natural convection cooling
- Operating Temperature: 0°C to 50°C (32°F to 122°F)
- Storage Temperature: -25°C to 70°C (-13°F to 158°F)
- Humidity: 5% to 95% RH, non-condensing
- Mounting: Standard Yokogawa rack mounting
- Weight: Approximately 2.2 kg (4.85 lbs)
- Certifications: CE, UL, and CSA compliant for industrial standards
Applications
- Industrial Automation: Supports DCS and other automation systems.
- Stable Power Delivery: Ensures reliable operation of essential components.
- Seamless Integration: Fits easily into Yokogawa’s system infrastructure.
Yokogawa |CP401-10 | Processor Module
Yokogawa |CP401-10 | Processor Module
Description
The Yokogawa CP401-10 is a reliable and efficient power supply module designed to support Yokogawa’s distributed control systems (DCS) and other automation applications. It provides stable DC power, ensuring consistent performance and reliability in various industrial environments. The module integrates seamlessly with Yokogawa’s system infrastructure, delivering secure power to essential components.
Technical Specifications
- Model Number: CP401-10
- Type: Power Supply Module
- Input Voltage Range: 100 to 240 V AC
- Input Frequency: 50/60 Hz
- Output Voltage: 24 V DC nominal
- Output Current: 10 A maximum
- Efficiency: ≥85% at full load
- Protection: Overload, over-voltage, and short-circuit protection
- Cooling Method: Natural convection cooling
- Operating Temperature: 0°C to 50°C (32°F to 122°F)
- Storage Temperature: -25°C to 70°C (-13°F to 158°F)
- Humidity: 5% to 95% RH, non-condensing
- Mounting: Standard Yokogawa rack mounting
- Weight: Approximately 2.2 kg (4.85 lbs)
- Certifications: CE, UL, and CSA compliant for industrial standards
Applications
- Industrial Automation: Supports DCS and other automation systems.
- Stable Power Delivery: Ensures reliable operation of essential components.
- Seamless Integration: Fits easily into Yokogawa’s system infrastructure.