Woodward | 9907-005 | Load Control Module
- Operating Temperature: –40 to +70 °C (–40 to +158 °F)
- Storage Temperature: –55 to +105 °C (–67 to +221 °F)
- Humidity: 95% at 38 °C
- Electromagnetic Susceptibility: ANSI/IEEE C37.90.2; ANSI C37.90.1-1989
- Mechanical Shock: US MIL-STD 810C, Method 516.2, Procedures I, II, V
- Vibration: US MIL-STD 167, Type I
Electrical Specifications
Control Power Supply Input
- Operating: 8–32 Vdc continuous (as low as 10 Vdc, 1.8 A max, or as high as 77 Vdc for up to 5 min)
- Reverse: –56 Vdc continuous
- Burden: 18 W, 1 A maximum
Voltage Sensing Inputs
- 120 Vac Input (L–N) Wye PT Configuration: 65–150 Vac, terminals 4–5, 7–12, 9–12, and 11–12
- 240 Vac Input (L–N) Wye PT Configuration: 150–300 Vac, terminals 3–5, 6–12, 8–12, and 10–12
- 120 Vac Open Delta PT Configuration: 65–150 Vac, terminals 3–5, 6–8, 8–10, and 10–6
- 240 Vac Open Delta PT Configuration: 150–300 Vac, terminals 3–5, 6–8, 8–10, and 10–6
- Phases: Three phase utility bus, single phase generator bus
- Frequency: 45–66 Hz
- Burden: Less than 0.1 VA per phase
- Accuracy: 0.1% of full scale
Current Transformer Inputs (CTs)
- Current: 0–5 Arms, 7 Arms max.
- Frequency: 56 to 66 Hz
- Burden: Less than 0.1 VA per phase
- Accuracy: 0.1% of full scale
- Phases: Three phase utility bus
Discrete Inputs
- Voltage: 18–40 Vdc @ 10 mA
Analog Inputs
- Current: 4–20 mA @ 243 Ω
- Voltage: 1–5 Vdc @ 10 kΩ
Analog Outputs
- Speed Bias: ±2.5 Vdc, 0.5–4.5 Vdc, 1–5 Vdc across 243 Ω, or 500 Hz PWM
- Voltage Bias: High in ±9 Vdc, low in ±3 Vdc, current 50 mA
Relay Driver Outputs
- Voltage: 18–40 Vdc @ 200 mA sink
Local Area Network
- Technology: Echelon LonWorks Technology
- Protocol: Standard Protocol
- Speed: 1.25 MBPS
Calibration and Diagnostics Port
- Interface: RS-422
Compliance
- UL/cUL: Listed
Technical Manual
- Manual Number: 02022
Woodward | 9907-005 | Load Control Module
Current product
Current
Vendor:
Woodward
Woodward | 9907-005 | Load Control Module
Regular price
$200.00
Sale price
$200.00
Regular price
$300.00
Options
Descriptions
- Operating Temperature: –40 to +70 °C (–40 to +158 °F)
- Storage Temperature: –55 to +105 °C (–67 to +221 °F)
- Humidity: 95% at 38 °C
- Electromagnetic Susceptibility: ANSI/IEEE C37.90.2; ANSI C37.90.1-1989
- Mechanical Shock: US MIL-STD 810C, Method 516.2, Procedures I, II, V
- Vibration: US MIL-STD 167, Type I
Electrical Specifications
Control Power Supply Input
- Operating: 8–32 Vdc continuous (as low as 10 Vdc, 1.8 A max, or as high as 77 Vdc for up to 5 min)
- Reverse: –56 Vdc continuous
- Burden: 18 W, 1 A maximum
Voltage Sensing Inputs
- 120 Vac Input (L–N) Wye PT Configuration: 65–150 Vac, terminals 4–5, 7–12, 9–12, and 11–12
- 240 Vac Input (L–N) Wye PT Configuration: 150–300 Vac, terminals 3–5, 6–12, 8–12, and 10–12
- 120 Vac Open Delta PT Configuration: 65–150 Vac, terminals 3–5, 6–8, 8–10, and 10–6
- 240 Vac Open Delta PT Configuration: 150–300 Vac, terminals 3–5, 6–8, 8–10, and 10–6
- Phases: Three phase utility bus, single phase generator bus
- Frequency: 45–66 Hz
- Burden: Less than 0.1 VA per phase
- Accuracy: 0.1% of full scale
Current Transformer Inputs (CTs)
- Current: 0–5 Arms, 7 Arms max.
- Frequency: 56 to 66 Hz
- Burden: Less than 0.1 VA per phase
- Accuracy: 0.1% of full scale
- Phases: Three phase utility bus
Discrete Inputs
- Voltage: 18–40 Vdc @ 10 mA
Analog Inputs
- Current: 4–20 mA @ 243 Ω
- Voltage: 1–5 Vdc @ 10 kΩ
Analog Outputs
- Speed Bias: ±2.5 Vdc, 0.5–4.5 Vdc, 1–5 Vdc across 243 Ω, or 500 Hz PWM
- Voltage Bias: High in ±9 Vdc, low in ±3 Vdc, current 50 mA
Relay Driver Outputs
- Voltage: 18–40 Vdc @ 200 mA sink
Local Area Network
- Technology: Echelon LonWorks Technology
- Protocol: Standard Protocol
- Speed: 1.25 MBPS
Calibration and Diagnostics Port
- Interface: RS-422
Compliance
- UL/cUL: Listed
Technical Manual
- Manual Number: 02022