Honeywell | LG1093AC01 | LG1093 Flame Detector
Overview
LG1093AC01 is a Honeywell flame detector designed for use with gas turbines, offering high sensitivity to UV radiation in the 180–260nm range. It provides quick flame detection and is suitable for a variety of industrial applications.
Features
- Sensor Type: Geiger Mueller-type phototube
- Flame Detection: UV radiation detection, solar blind
- Response Time: Flame present: 0.1 sec, flame loss: 0.2 sec
- Distance: Operates up to 330m (1000ft)
- Temperature Range: -40°C to 176°C
Electrical
- Hardware Outputs: For EG1033 amplifier modules only
- Voltage Support: 28 Vdc, 20-35 Vdc, 115 Vac
- Amplifier Types: Open collector (EG1033AA), relay contacts (EG1033AB, EG1033AC)
Approvals & Certification
- CE Mark: EMC, LVD, ATEX (EEx d IIA T3, Zone 1 and 2)
- Factory Mutual: Approval for explosive atmospheres
- Applications: Power generation, compressors, gas turbines
Installation & Specifications
- Cable Length: 9ft (2.7m)
- Flange Size: 1.73" O.D. x 0.14" wide
- Weight: 0.91 Kg
- Viewing Window: Rated to 428mbar (6.3psi)
Notes
- Limitations: Not recommended for GE/NP DLE gas turbines (Low-NOx)
- MTBF: 10,000 hours with over 1 billion operating hours
Honeywell | LG1093AC01 | LG1093 Flame Detector
Honeywell | LG1093AC01 | LG1093 Flame Detector
Overview
LG1093AC01 is a Honeywell flame detector designed for use with gas turbines, offering high sensitivity to UV radiation in the 180–260nm range. It provides quick flame detection and is suitable for a variety of industrial applications.
Features
- Sensor Type: Geiger Mueller-type phototube
- Flame Detection: UV radiation detection, solar blind
- Response Time: Flame present: 0.1 sec, flame loss: 0.2 sec
- Distance: Operates up to 330m (1000ft)
- Temperature Range: -40°C to 176°C
Electrical
- Hardware Outputs: For EG1033 amplifier modules only
- Voltage Support: 28 Vdc, 20-35 Vdc, 115 Vac
- Amplifier Types: Open collector (EG1033AA), relay contacts (EG1033AB, EG1033AC)
Approvals & Certification
- CE Mark: EMC, LVD, ATEX (EEx d IIA T3, Zone 1 and 2)
- Factory Mutual: Approval for explosive atmospheres
- Applications: Power generation, compressors, gas turbines
Installation & Specifications
- Cable Length: 9ft (2.7m)
- Flange Size: 1.73" O.D. x 0.14" wide
- Weight: 0.91 Kg
- Viewing Window: Rated to 428mbar (6.3psi)
Notes
- Limitations: Not recommended for GE/NP DLE gas turbines (Low-NOx)
- MTBF: 10,000 hours with over 1 billion operating hours