The 140CRP81100 is a Profibus DP Master Communications Module for Schneider Electric's Quantum Automation Series. It provides seamless interface capabilities to Profibus-DP networks, enabling communication between field devices and control systems.
Specifications
-
Programming Software:
- Modsoft version 2.32 or greater
- Concept version 2.2 or greater
-
Bus Current Required: 1.2 A
-
Power Dissipation: 6.5 W
Data Interface
- RS-232C: 9-pin D-shell, non-isolated, shielded cable, 3 m max, 19.2 Kbps default
- RS-485: Profibus, up to 12 Mbps
Installation
- Installation Type: Local backplane only
Bus Specifications
-
Maximum Bus Nodes: 32
-
Bus Lengths (at 12 Mbps cable):
- 1.2 km at 9.6 Kbps
- 1.2 km at 19.2 Kbps
- 1.2 km at 93.75 Kbps
- 1.0 km at 187.5 Kbps
- 0.5 km at 500 Kbps
- 0.2 km at 1.5 Mbps
- 0.1 km at 3 Mbps
- 0.1 km at 6 Mbps
- 0.1 km at 12 Mbps
-
Transmission Media: Shielded twisted pair
-
Connection Interface: EIA RS-485
Communication & Protocol
- Node Type: Master class 1
- Bus Access Procedure: Master/slave to DP bus slaves
- Transmission Procedure: Half-duplex
- Frame Length: Max. 255 bytes
- Data Unit Length: Max. 246 bytes
- Data Security: Hamming distance, HD = 4
- Node Addresses: 1...126
140CRP81100 | SCHNEIDER | Profibus DP Master Communications Module
140CRP81100 | SCHNEIDER | Profibus DP Master Communications Module
Overview
The 140CRP81100 is a Profibus DP Master Communications Module for Schneider Electric's Quantum Automation Series. It provides seamless interface capabilities to Profibus-DP networks, enabling communication between field devices and control systems.
Specifications
-
Programming Software:
- Modsoft version 2.32 or greater
- Concept version 2.2 or greater
-
Bus Current Required: 1.2 A
-
Power Dissipation: 6.5 W
Data Interface
- RS-232C: 9-pin D-shell, non-isolated, shielded cable, 3 m max, 19.2 Kbps default
- RS-485: Profibus, up to 12 Mbps
Installation
- Installation Type: Local backplane only
Bus Specifications
-
Maximum Bus Nodes: 32
-
Bus Lengths (at 12 Mbps cable):
- 1.2 km at 9.6 Kbps
- 1.2 km at 19.2 Kbps
- 1.2 km at 93.75 Kbps
- 1.0 km at 187.5 Kbps
- 0.5 km at 500 Kbps
- 0.2 km at 1.5 Mbps
- 0.1 km at 3 Mbps
- 0.1 km at 6 Mbps
- 0.1 km at 12 Mbps
-
Transmission Media: Shielded twisted pair
-
Connection Interface: EIA RS-485
Communication & Protocol
- Node Type: Master class 1
- Bus Access Procedure: Master/slave to DP bus slaves
- Transmission Procedure: Half-duplex
- Frame Length: Max. 255 bytes
- Data Unit Length: Max. 246 bytes
- Data Security: Hamming distance, HD = 4
- Node Addresses: 1...126