Bently Nevada | 60M100-00 | Condition Monitoring System

SKU: 60M100-00
  • Manufacturer: BENTLY NEVADA

  • Product No.: 60M100-00

  • Condition:في الأوراق المالية

  • Product Type: Condition Monitoring System

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 1400g

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

  • Manufacturer: Bently Nevada
  • Model: 60M100-00
  • Product Type: Condition Monitoring System

Configurations

  • Independent, standalone condition monitoring system
  • Networked, distributed collection of inter-operating systems
  • Integrated part of a machine OEM's control and instrumentation package

Electrical Specifications

  • Input Power: Min: 18 Vdc, Max: 36 Vdc
  • Current Max: 1.7 A
  • Inrush Current Max: 2.7 A (less than 5 ms)
  • Module Inputs Max: 12 dynamic signals and 2 Keyphasor signals
  • Dynamic Range: 110 dB @ fs = 102.4 ksps
  • Signal/Noise Ratio: 110 dB @ fs = 102.4 ksps
  • A/D Conversion: Sigma-Delta 24 bits nominal
  • Bandwidth: 0 to 40 kHz

Outputs

  • Two Independent Ethernet Ports:
    • Net A: 10/100 BaseT, Network DHCP Port
    • Net B: 10/100 BaseT, Local Static IP Port
  • Buffered Signal Outputs: Two 15-pin DSUB connectors, 550-ohm output impedance

LED Indicators

  • POWER LED: Indicates proper power input
  • OK LED: Indicates system is functioning properly
  • Danger LED: Indicates a danger alarm condition
  • Alert LED: Indicates an alert condition
  • Kph 1 OK LED: Indicates Keyphasor signal 1 is triggering
  • Kph 2 OK LED: Indicates Keyphasor signal 2 is triggering
  • Net A: Indicates valid link on Network A
  • TX/RX A: Indicates network traffic on Network A
  • Net B: Indicates valid link on Network B
  • TX/RX B: Indicates network traffic on Network B

Accuracy

  • Direct pk or rms: Within ± 0.5% of full-scale typical, ± 1.1% worst case
  • Bias: +0.4 V / -0.8 V typical, +0.8 V / -1.34 V worst case
  • Rotor, Mesh, and Fault Frequencies: ± 6.7% typical, ± 9.7% worst case
  • Bearing Frequencies: ± 6.7% typical, ± 9.7% worst case
  • Tower Sway: ± 0.16 m/s² (0.016 g) typical, ± 0.23 m/s² (0.023 g) worst case
  • Kurtosis: ± 1% (50 Hz to 10,000 Hz), ± 3% (1 Hz to 49.9 Hz)
  • Generator Electrical Noise: ± 1% (50 Hz to 10,000 Hz), ± 3% (1 Hz to 49.9 Hz)
  • Crest Factor: Within ± 0.5% of full-scale typical, ± 1.1% worst case
  • Minimum Amplitude for Measurements: 0.6 m/s² (0.06 g)

Alarming Modes

  • Modes:
    • Mode 1: 25% to 40% power
    • Mode 2: > 40% to 55% power
    • Mode 3: > 55% to 70% power
    • Mode 4: > 70% to 85% power
    • Mode 5: > 85% power
  • Setpoints: 2 levels: Warning and Alarm
  • Time Delay: 300 seconds (fixed) for all measurements
  • Latching: All alarm statuses are latching

Weight

  • 1.4 kg (3 lbs)

Mounting

  • DIN rail mounting
معلومات الطلب والضمان

شروط الشراء والإرجاع

إرشادات مفصلة حول الحد الأدنى لكمية الطلب ومواعيد التسليم وخيارات الدفع والضمان وسياسات الإرجاع.

نحن نقبل بكل سرور الطلبات بالجملة، مع الحد الأدنى لكمية الطلب وهو وحدة واحدة فقط.

عند الطلب، يمكننا تقديم جميع المستندات اللازمة، بما في ذلك شهادات المنشأ/المطابقة وغيرها من أوراق التصدير المطلوبة.

نحن نقبل الدفع بنسبة 100% T/T (التحويل البرقي) قبل الشحن. بالنسبة للعناصر التي تتطلب مهلة زمنية، يلزم إيداع 30% مقدمًا، مع دفع 70% المتبقية قبل الشحن. بالنسبة للتحويلات بالرنمينبي، يرجى الاتصال بنا إذا كان لديك وكيل في الصين.

جميع العناصر الجديدة والأصلية تأتي مع ضمان قياسي لمدة عام واحد. للحصول على خيارات الضمان الممتد، لا تتردد في الاتصال بنا للحصول على تفاصيل التسعير.

نحن نعطي الأولوية لرضاك. إذا كنت بحاجة إلى إرجاع منتج ما، فيجب أن يتم ذلك خلال 30 يومًا من تاريخ الشراء. يجب أن يكون المنتج غير مستخدم، وغير مفتوح، وفي عبوته الأصلية، بما في ذلك جميع الملحقات. ستتم معالجة المبالغ المستردة خلال 5-7 أيام عمل من استلام المرتجع. يرجى ملاحظة أن رسوم الشحن والمناولة غير قابلة للاسترداد.

مقارنة السلعة